Teseq/AMETEK阿美特克
CTS - Compliance Test Studio CTS-FLX 汽车供电电压变化模拟器 详细指标
Windows 11 (64-bit) · Intel Core i5 or AMD equivalent (quad core or better)
详细指标
下表为该产品(系列)官网/datasheet 公布的参数,行名保留英文原名并加中文标注;数值单位与测试条件以厂家原表为准。
规格(第3页)
• Operating System:Windows 11 (64-bit)
• Processor:Intel Core i5 or AMD equivalent (quad core or better)
• Memory (RAM):16 GB minimum
• Graphics:must support direct3D Feature Level 11 or higher
• Storage:10 GB of free space
• Interfaces(接口):USB,GPIB,Ethernet,OptoLink (depending on the devices to be controlled)
• Supported devices:check application specific datasheet for list of supported devices
规格(第4页)
• License:Description
• CTS-FLX.CORE:The main license for the Compliance Test Studio,additional licenses may be required depending on the desired functionality
• CTS-FLX.DeviceControl:Enables the "device" mode to remotely control the connected devices
• CTS-FLX.Reporting:License for the Report Generator and Manager
• CTS-FLX.ExtFunctions:Extended functions including Report Manager,Link Test,Flow Chart,Measuring Instruments,Iteration,Interlink,Import and Export of Test Data
• CTS-FLX.FastSwitching:License for CTS to enable 标准 test library for Micro Interrupts and GMW 3172, test 9.2.18, requires PFM 200N
• CTS-FLX.ExtSources:License to control external sources with AutoWave (via analog signal)
• CTS-FLX.EnhancedAnalysis:Enhanced analysis for harmonics and flicker measurements,deep insight in test data per time window,fluctuating/average harmonics,最小-最大 values etc.
• CTS-FLX.Industry:Library with pre-programmed tests for Industry Standards (IEC,GB,BS,DIN,etc.),the available standards depend on the used devices: e.g. IEC 61000-3-2/-12 harmonics and IEC 61000-3-3/-11 flicker in combination with a DPA 50xN,IEC 61000-4-13/-14/-28 etc. in combination with a NetWave/PowerWave
• CTS-FLX.Automotive-INTL:Library with pre-programmed tests for Low and High Voltage Automotive International standards (e.g. ISO),valid for all licensed devices
• CTS-FLX.Automotive-MFR:Library with pre-programmed tests for Low and High Voltage Automotive OEM/Manufacturer standards (e.g. Stellantis,Volkswagen,Mercedes,etc.),special licenses for Nissan and Renault on request,valid for all licensed devices
• CTS-FLX.Automotive-HnF:Library with pre-programmed tests for Harmonics and Flicker Automotive standards (e.g. ECE R10, IEC 61851, Stellantis,Volkswagen,Mercedes,etc.),special licenses for Nissan and Renault on request,requires a DPA 50xN or NetWave with Opt-NWB (harmonics only).
• CTS-FLX.Aircraft-INTL:Library with pre-programmed tests for Aircraft standards (e.g. DO-160 D/E/F/G Section 16 and 18, ED-14G Section 16 and 18, GOST 19705-89, JIS W0812),valid for all licensed devices
• CTS-FLX.Aircraft-Airbus:Library with pre-programmed tests for Airbus aircraft standards ABD0100.1.2, ABD100.1.8, ABD0100.1.8.1, AMD-24, valid for all licensed devices
• CTS-FLX.Aircraft-Boeing:Library with pre-programmed tests for Boeing aircraft standards 787B3-147 and 7E7B3- 147, valid for all licensed devices
• CTS-FLX.Military:Library with pre-programmed tests for Military standards (e.g. MIL-STD 461, MIL-STD 704),valid for all licensed devices within one system,requires a NetWave and a device license
• CTS-FLX.Space:Library with pre-programmed tests for Space standards (e.g. AIAA S-121A,ECSS-E-ST-20- 07C,NASA GSFC-STD-7000B)
• All library licenses require at least CTS-FLX.CORE and CTS-FLX.DeviceControl. They enable all tests within the licensed standards library that are supported by the licensed device(s).
• Maintenance
• MNT maintenance provides access to software updates, new features, bug fixes and standards library updates. Every new license includes 12 months of maintenance for the CORE and the purchased or included standards libraries (e.g. CTS-FLX.Industry). Maintenance can be extended upfront to 24 or 36 months. Maintenance renewals are available after the initial coverage period. Each library section requires its own maintenance (Industry, Automotive, Military, Aircraft and Space).
• CTS-FLX.CORE-MNT12 / 24 / 36:Maintenance for the CORE license. Available for 12, 24, or 36 months and includes all CTS-FLX releases during the active maintenance period.
• CTS-FLX.Industry-MNT12 / 24 / 36:Maintenance for the Industry Standards Library. Available for 12, 24, or 36 months and includes all library updates. Requires CTS-FLX.CORE-MNT.
• CTS-FLX.Automotive-MNT12 / 24 / 36:Maintenance for the Automotive Standards Library. Available for 12, 24, or 36 months and includes all library updates. Requires CTS-FLX.CORE-MNT.
• CTS-FLX.Military-MNT12 / 24 / 36:Maintenance for the Military Library. Available for 12, 24, or 36 months and includes all library updates. Requires CTS-FLX.CORE-MNT.
• CTS-FLX.Aircraft-MNT12 / 24 / 36:Maintenance for the Aircraft Standards Library. Available for 12, 24, or 36 months and includes all library updates. Requires CTS-FLX.CORE-MNT.
• CTS-FLX.Space-MNT12 / 24 / 36:Maintenance for the Space Standards Library. Available for 12, 24, or 36 months and includes all library updates. Requires CTS-FLX.CORE-MNT.
适用标准
• Automotive Standards:ISO/TR 7637-4、ISO 21498
• Automotive OEM Specifications:VW 80300、LV 123、BMW GS 95002、BMW GS 95003-2、Ford EMC-CS-2009.1、Mazda MES PW 67602、PSA B21 7110、GWT A D05-02、Hyundai Kia ES 96200-00、VW 80303、BMW GS 95002-3、Ford FMC 1280、Mercedes MBN 11123、PSA B21 7112、BMW GS 95023、Mercedes MBN LV123、PSA B21 7111、Rivian RTS-3653、Stellantis CS.00245、Fisker FSK-FM29-CES-014、Scania TB4378
• IEC / EN Basic Standards:IEC 61000-3-2、IEC 61000-3-12、IEC 61000-3-3、IEC 61000-3-11、IEC 61000-4-8、IEC 61000-4-11、IEC 61000-4-13、IEC 61000-4-14、IEC 61000-4-15、IEC 61000-4-28、IEC 61000-4-34、IEC TS 61000-3-16
• Military and Aerospace:MIL-STD 461、RTCA/DO 160、Airbus ABD 100、Airbus AMD-24、Boeing 787B3-147、GJB 181、MIL-STD 704、MIL-STD 1275、MIL-STD 1399