DCD 5 series 雷击浪涌与电快速瞬变脉冲群发生器 详细指标
5 kV · 5 kV
详细指标
下表为该产品(系列)官网/datasheet 公布的参数,行名保留英文原名并加中文标注;数值单位与测试条件以厂家原表为准。
规格(第3页)
• Impulse voltage Surge:5 kV
• Impulse voltage Ringwave:5 kV
• Impulse voltage Burst:5 kV
• Line voltage / current:DPM 50/DPM 50-1: 最大 35 V AC / 50 V DC, 4 A / 最大. 300 V AC / 420 V DC, 4 A
• VPM 250-100: max. 250 V AC / 350 V DC, 4 A
• Coupling mode:0.5 µF capacitor via 40 Ohm GDT gas arrestor via 40 Ohm ABD breaking diode via 40 Ohm 0.5 µF capacitor via 500 Ohm / Common mode and unsymmetrical coupling. C coupling 33 nF to each line,switchable L1, L2, L3, L4, L5, L6, L7, L8, all combinations possible
• Ringwave coupling:> 3 µF capacitor
• Decoupling inductance:20 mH,each line / >100 µH
• Decoupling / Filter capacitor:Ferrite / 10 nF each line
• AE Protection:DPM 50-1 (2 modules with 4 lines included) Impedance to GND: 1 kOhm DPM 50 (optional, 2 required) Impedance to GND: open circuit VPM 250-100 (optional, 2 required) Impedance to GND: 100 kOhm
• Input from generator:4 mm safety banana plugs at back / 50 Ohm SHV connector at front
• EUT connectors:4 mm safety banana plugs / 4 mm safety banana plugs
• HV/COM output:Surge-out on front panel,switchable via compact NX generator
规格(第4页)
• DCD 5 sr-4-1:5 kV, 4 lines, 1 A / DCD 5 st-4-1 / 5 kV, 4 lines (2 pairs), 1 A
• DCD 5 sr-4-4:5 kV, 4 lines, 4 A,intermittent 5 A / DCD 5 st-8-1 / 5 kV, 8 lines (4 pairs), 1 A
• DCD 5 sr-8-1:5 kV, 8 lines, 1 A / Line voltage / Depends on AE protection module
• DCD 5 sr-8-4:5 kV, 8 lines, 4 A,intermittent 5 A / General data
• Line voltage:Depends on AE protection module / Coupling / Selectable: - GDT gas arrestor (90 V) - ABD Plug: Avalanche Breaking Diode (140 V) - Individual CD (coupling device)
• General data
• Surge coupling:as per Fig. 9 IEC 61000-4-5 Ed. 3, - 0.5 µF capacitor via 40 Ohm - GDT gas arrestor (90 V) via 40 Ohm
• Ringwave coupling:as per Fig. 8 IEC 61000-4-12 Ed. 3, > 3 µF capacitor / Matching resistor Rc / Surge Pulse 1.2/50 µs, 8 x 320 Ohm (4 pairs), 4 x 160 Ohm (2 pairs), 2 x 80 Ohm (1 pair)
• Decoupling inductance:20 mH,each line
• AE Protection modules:Matching resistor Rc / Telecom Surge 10/700 µs, 8 x 25 Ohm (8 lines, 4 pairs) 4 x 25 Ohm (4 lines, 2 pairs)
• DPM 50-1, included:Diode Protection Module 50 V,Impedance to GND: 1 kOhm 1 module is included for every 4 lines. Line voltage: 最大. 35 V AC, 50 V DC
• Decoupling(去耦):20 mH,pairwise current compensated
• Residual voltage at AE port, 5 kV pulse:st-4-1: 88 V (1.2/50 µs), 80 V (10/700 µs) st-8-1: 85 V (1.2/50 µs), 60 V (10/700 µs)
• DPM 50, optional:Diode Protection Module 50 V,Impedance to GND: open circuit 1 module is required for every 4 lines. Line voltage: 最大. 35 V AC, 50 V DC
• Signal Bandwith:100 kHz with 600 Ohm load
• Data rate:up to 1MBit/s
• AE Protection modules:Similar to DCD 5 sr
• VPM 250-100, optional:Varistor Protection Module 250 V,Impedance to GND: 100 kOhm 1 module is required for every 4 lines. Line voltage: 最大. 250 V AC, 350 V DC / Included accessories / st-4-1: 1 x DPM 50-1, 4 x GDT (90 V), 4 x ABD (140 V) 4 x short circuit connectors 2 x 0.25 m safety lab cables
• Required modules:DCD with 4 lines: 1 DCD with 8 lines: 2 / st-8-1: 2 x DPM 50-1, 8 x GDT (90 V), 8 x ABD (140 V) 8 x short circuit connectors 6 x 0.25 m safety lab cables
• Optional coupling device:ABD Plug: Avalanche Breaking Diode (140 V),for Surge & Ringwave,最大. 7 kV
• Connectors
• Input from generator:4 mm safety banana plugs at back
• EUT:4 mm safety banana plugs
规格(第4页)
• DIMENSION AND WEIGHT
• DCD 5 sr, 5 st, 5-A b:3 HU, 19", 447 mm x 500 mm x 153 mm (LxWxH), 12-22 kg
• DCD 5-A sr:6 HU, 19", 447 mm x 500 mm x 286 mm (LxWxH), 20 kg
• ENVIRONMENT
• Temperature:10 °C to 40 °C
• Humidity(湿度):10 % to 80 %,non condensing
• Atmospheric pressure:86 kPa (860 mbar) to 106 kPa (1060 mbar)
适用标准
• IEC / EN Basic Standards:IEC 61000-4-4、IEC 61000-4-5、IEC 61000-4-12
• Telecom / ITU:ITU-T K.17、ITU-T K.20、ITU-T K.28、ITU-T K.45
• IEC / EN Generic Standards:EN 61000-6-1、EN 61000-6-2