Model overview
• Parameter:HMP2020 HMP2030 HMP4030 HMP4040
• Number of output channels:2 | 3 | 3 | 4
• Maximum output current per channel:channel 1: 10 A, channel 2: 5 A | 5 A | 10 A | 10 A
• Maximum output power per channel:channel 1: 160 W, channel 2: 80 W | 80 W | 160 W | 160 W
• Total output power:max. 188 W max. 188 W max. 384 W max. 384 W
• Output voltage per channel:0 V至32 V | 0 V至32 V | 0 V至32 V | 0 V至32 V
• Key facts:Benefits
higher currents possible in p arallel operation
• Elec tronic fuse (OCP), adjust able maximum volt age (OVP),:page 7
► Tailored for specific applic ations
• Benefits:Unique fe atures such as
NEEDS
• that might need +12 V/-12 V, for example, and avoids any:+12 V
ground problems in complex DUTs.
• -12 V
age to the test circuit in the event of a fault.
• R&S®HMP2020 two-channel instrument:R&S®HMP2030 three-channel instrument
• are always shown on the display.:overload.
and a message will be displayed.
• R&S®HMP4030 three-channel instrument:R&S®HMP4040 four-channel instrument
EASY OPERATION
• Intuitive to use:EasyArb function for all channels
systems.
• Connections for all channels -:including
• sense lines - are also:provided on the rear
Specification limit
• Measurement uncertainties:Guard bandX-axis
Electrical specifications
• Number of output channels:HMP2020 | 2
• HMP:3
• HMP:3
• HMP:4
• Maximum output power:HMP2020/R | 188 W
• HMP4030/R:384 W
• Maximum output power per channel:HMP2020 channel 1: 160 W; channel 2: 80 W
• HMP:80 W
• HMP4030/R:160 W
• Output voltage per channel:all models | 0 V至32 V
• Maximum output current per channel:HMP2020 channel 1: 10 A; channel 2: 5 A
• HMP:5 A
• HMP4030/R:10 A
• Maximum voltage in serial operation:HMP2020 | 64 V
• HMP2030/R:96 V
• HMP:128 V
• HMP:30 A
• HMP:40 A
• Voltage ripple:20 Hz至20MHz | < 1.5 mV (RMS) (meas.)
• Current ripple:< 1 mA (RMS) (meas.)
• Load regulation:load change from 10 % to 90 %
• 电压:±(% of output + offset) | < 0.01 % + 2 mV
• 电流:±(% of output + offset) | < 0.01 % + 250 μA
• Line regulation:±10 % change in mains voltage
• 电压:±(% of output + offset) | < 0.01 % + 2 mV
• 电流:±(% of output + offset) | < 0.01 % + 250 μA
Programming resolution
• 电压:1 mV
• 电流:R&S®HMP2020 channel 1 (10 A) | < 1 A: 0.2 mA; ≥ 1 A: 1 mA
• R&S®HMP2020 channel 2 (5 A):< 1 A: 0.1 mA; ≥ 1 A: 1 mA
• HMP:< 1 A: 0.1 mA; ≥ 1 A: 1 mA
• HMP4030/R:< 1 A: 0.2 mA; ≥ 1 A: 1 mA
Programming accuracy
• 电压:±(% of output + offset) | < 0.0 5 % + 5 mV
• 电流:±(% of output + offset) | < 0.1 % + 5 mA
Output measurements
• Measurement functions:voltage, current
Readback resolution
• 电压:1 mV
• 电流:R&S®HMP2020 channel 1 (10 A) | < 1 A: 0.2 mA; ≥ 1 A: 1 mA
• R&S®HMP2020 channel 2 (5 A):< 1 A: 0.1 mA; ≥ 1 A: 1 mA
• HMP:< 1 A: 0.1 mA; ≥ 1 A: 1 mA
• HMP4030/R:< 1 A: 0.2 mA; ≥ 1 A: 1 mA
Readback accuracy
• 电压:±(% of output + offset) | < 0.0 5 % + 5 mV
• 电流:±(% of output + offset) | < 0.1 % + 2 mA
• Temperature coefficient (per °C):+5 °C to +20 °C and +30 °C to +40 °C
• 电压:±(% of output + offset) | 0.01 % + 2 mV
• 电流:±(% of output + offset) | 0.02 % + 3 mA
• Remote sensing:yes, for each channel
• Maximum sense compensation:1 V
Ratings
• Maximum voltage to earth:150 V (peak)
outputs
• Maximum reverse current:for 5 minutes max. | 5 A
Remote control mode
• Command processing time:< 50 ms (nom.)
Protection functions
• Overvoltage protection:configurable for each channel
• Response time:(Iload > Iresponse × 2) | < 10 ms
• Fuse linking (FuseLink function):yes
• Overtemperature protection:independent for each channel
Arbitrary function (EasyArb)
• Parameters:voltage, current, time
• Maximum number of points:128
• Dwell time:10 ms至60 s
• 10 instrument settings
Display and interfaces
• 显示屏:HMP2020/R | 240 × 64 pixel LCD
• HMP4030/R:240 × 128 pixel LCD
• Front panel connections:channel outputs | 4 mm safety sockets
• Remote control interfaces:optional dual interface USB (TMC/CDC)/LAN
(R&S®HO732)
• optional:dual interface RS-232/USB (R&S®HO720)
• optional:IEEE-488 (GPIB) (R&S®HO740)
Environmental conditions
• storage temperature range:20°C to | +70°C
• 湿度:noncondensing | 5 % to 80 %
• Altitude:operating altitude max. 2000 m above sea level
Power rating
• Mains nominal voltage:115 V/230 V (±10 %); CAT II
• Mains frequency:50 Hz至60Hz
• Maximum power consumption:HMP2020/R | 300 W
• HMP4030/R:600 W
• Mains fuses (115 V power source):HMP2020/R | 2 × T6.3H/250 V
• HMP4030/R:2 × T10H/250 V
• Mains fuses (230 V power source):HMP2020/R | 2 × T3.15H/250 V
• HMP4030/R:2 × T5H/250 V
applied harmonized standards:
• E:N | 6 | 1 | 3 | 2 | 6 | 1
• Electromagnetic compatibility:EU: EN 613 26 -2-1
• in line with EU EMC Directive 2014/30/EU:EN | 55 011 (Cl ass A )
► EN 61000 -3-3
• Korea:KC mark
• USA, Canada:CSA C22.2 No. 61010-1
• RoHS:in line with EU Directive 2011/65/EU EN IEC | 63000
Mechanical resistance
• 5 Hz至55Hz, 0.15 mm amplitude const.,
• Vibration:sinusoidal | 55 Hz至155Hz, 0.5 g const.,
• in line with EN:60068-2-6
• random:8 Hz至500Hz, 1.2 g (RMS), in all 3 axes,
• in line with EN:60068-2-64
机械数据
• Dimensions (W × H × D):HMP2020/R | 285 mm × 95 mm × 40 5 mm
(11.22 in × 3.74 in × 15.94 in)
• HMP4030/R:285 mm × 136 mm × 40 5 mm
(11.22 in × 5.35 in × 15.94 in)
• 重量:HMP2020 | 7.8 kg (17.2 lb)
• HMP:8.0 kg (17.6 lb)
• HMP:12.4 kg (27.3 lb)
• HMP:12.8 kg (28.2 lb)
• Rack installation:HMP2020/R R&S®HZ42 option (19", 2 HU)
• HMP4030/R:R&S®HZP91 option (19", 4 HU)
订购信息
• Designation:Type Order No.
基本单元
• Two-channel power supply:HMP2020 | 3629.6718.02
• Three-channel power supply:HMP2030 | 3629.6718.03
• Three-channel power supply:HMP4030 | 3629.6776.03
• Four-channel power supply:HMP4040 | 3629.6776.04
Interface options
• Dual interface (USB/LAN):HO732 | 5800.3209.02
• Dual interface (RS-232/USB):HO720 | 3594.3660.02
• IEEE-488 (GPIB) interface:HO740 | 3622.3194.02
System components
• 19" rack adapter, 2 HU, for R&S®HMP2020/R&S®HMP:HZ42 | 3622.3207.02
• 19" rack adapter, 4 HU, for R&S®HMP4030/R&S®HMP:HZP91 | 5800.0939.02
保修
• Base unit:3 years
Service options
• Extended warranty, one year:WE1
• Extended warranty, two years:WE2 Please contact your local
• ment, technology systems and:networks & cybersecurity.
Trade names are trademarks of the owners