电源:外部供电
最大电流:10 A
模拟输出电压范围:0 V 至 60 V
总线连接器:PXI Express
PXIe, 1通道, 300 W, 60 V, 10 A PXI可编程电源
ONETEST 欢迎您
厂商登录 | 入驻
登录 | 注册 购物车 微信公众号厂商登录
电源:外部供电
最大电流:10 A
模拟输出电压范围:0 V 至 60 V
总线连接器:PXI Express
PXIe, 1通道, 300 W, 60 V, 10 A PXI可编程电源
以下指标取自 Teledyne 官方在线规格书,按原文档小节分组。
| 378996D-01 | April 2026 |
| 378996C-01 | March 2026 |
| 378996B-01 | October 2025 |
| 378996A-01 | September 2024 |
| HI terminal | HI force terminal connected to channel power stage (generates and/or dissipates power). Positive polarity is the voltage that is measured on HI > LO. |
| LO terminal | LO force terminal connected to channel power stage (generates and/or dissipates power). Positive polarity is the voltage that is measured on HI > LO. |
| HI S terminal | Voltage remote sense HI S input terminal. Used to compensate for I x R voltage drops in cable leads, connectors, and switches. |
| LO S terminal | Voltage remote sense LO S input terminal. Used to compensate for I x R voltage drops in cable leads, connectors, and switches. |
| GND () terminals | Tied to chassis ground through module front panel. Use for connections to cable shields. Do not use for grounding the LO force terminal due to pin current rating. |
| 1 | RSVD |
| 2 | RSVD |
| 3 | FAULT |
| 4 | INHIBIT |
| 5 | GND |
| 6 | RSVD |
| 7 | GND |
| 8 | GND |
| + | Auxiliary power input with positive polarity. |
| - | Auxiliary power input with negative polarity. |
| Dimensions | 3U, two-slot, PXI Express/cPCI Express module, 4.0 cm × 13.0 cm × 21.6 cm (1.6 in. × 5.1 in. × 8.5 in.) For more information, visit ni.com/dimensions and search by module number. |
| Weight | 650 g (22.9 oz) |
| Output | OMNIMATE Hybrid, 7.62 mm (4 position), 2.54 mm (6 position) |
| AUX I/O | MICRO COMBICON - DFMC 0, 5, 2.54 mm (8 position) |
| AUX Power In | MEGA-FIT RECEPTACLE, 5.7 mm (4 position) |
| Voltage | 6 V, 60 V |
| Minimum programmable voltage level | 10 mV |
| Minimum programmable voltage limit | 1% of range |
| Current | 100 mA, 1 A, 10 A |
| Minimum programmable current level | 0 A if the output voltage is ≥ 10 mV[3] |
| Minimum programmable current limit | 1% of range for the 100 mA and 1 A ranges, 150 mA for the 10 A range |
| Available DC output power[4] | 300 W |
| 6 V | 1 μV |
| 60 V | 10 μV |
| 100 mA | 10 nA |
| 1 A | 100 nA |
| 10 A | 10 μA |
| Voltage mode, ≤54 V step, unloaded | <4.7 ms, typical |
| Current mode, full-scale step, 10 A range | <3.1 ms, typical |
| Current mode, full-scale step, 1 A range | <3.3 ms, typical |
| Current mode, full-scale step, 100 mA range | <2.9 ms, typical |
| 10 A | <100 μs, typical to recover within ±300 mV |
| 1 A | <150 μs, typical to recover within ±10 mV |
| Voltage accuracy | Add 10 µV per volt of lead drop per ohm of corresponding sense lead resistance to voltage accuracy specifications. |
| Maximum sense lead resistance | 100 Ω |
| Maximum lead drop per lead | 1 V, maximum 60 V between HI and LO terminals |
| Voltage, local sense[11] | 15 μV/mA (15 mΩ), nominal; 30 μV/mA (30 mΩ), maximum |
| Voltage, remote sense | Error included in accuracy specifications. |
| Current | Error included in accuracy specifications. |
| Voltage | Error included in accuracy specifications. |
| Current | Error included in accuracy specifications. |
| Isolation voltage, any channel I/O pin[12] to earth ground | 150 V DC, CAT I |
| Transient overvoltage | 800 V peak |
| Absolute maximum voltage, between any channel I/O pin[13] and LO | 60 V |
| Any AUX I/O pin to ground | 5 V |
| AUX Power In + to AUX Power In – | ±60 V |
| AUX Power In – to ground | ±1 V |
| Overcurrent or overvoltage | Automatic shutdown, output disconnect relay opens |
| Reverse voltage protection | Automatic shutdown, output disconnect relay opens |
| Down programmer overload | Automatic shutdown, output disconnect relay opens |
| Overtemperature | Automatic shutdown, output disconnect relay opens |
| Overvoltage or undervoltage | Automatic shutdown, output disconnect relay opens |
| Overcurrent | Automatic shutdown, output disconnect relay opens, non-accessible fuse as backup protection |
| Available sample rates[14] | (1.8 MS/s)/N, nominal where S is samples N = 1, 2, 3, … 224 |
| Sample rate accuracy | Equal to PXIe_CLK100 accuracy, nominal |
| Maximum measure rate to host | 1.8 MS/s per channel, continuous, nominal |
| Maximum source update rate[15] | 100,000 updates/s, nominal |
| Source event delay | 10 μs, nominal |
| Source event jitter | 2 μs peak-to-peak, nominal |
| Measure event jitter | 2 μs peak-to-peak, nominal |
| Types | Start, Source, Sequence Advance, Measure |
| Polarity | Active high (not configurable) |
| Minimum pulse width | 100 ns |
| Polarity | Active high (not configurable) |
| Pulse width | >200 ns |
| Types | Source Complete, Sequence Iteration Complete, Sequence Engine Done, Measure Complete |
| Polarity | Active high (not configurable) |
| Pulse width | >230 ns |
| Direction | Output |
| Logic type | 3.3 V CMOS (open drain, internal pull-up) |
| Polarity | Active low (not configurable) |
| Output voltage range | 0 V to 3.3 V, typical |
| Output impedance (active low) | 50 Ω, nominal |
| Internal pull-up resistance | 10 kΩ, nominal |
| PXIe Chassis, +3.3 V | 1 A, maximum |
| PXIe Chassis, +12 V | 1 A, maximum |
| Auxiliary power source input | 45.6 VDC to 50.4 VDC, 9 A, maximum |
| Operating | 0 °C to 55 °C[16],[17] |
| Storage | -40 °C to 71 °C |
| Operating | 10% to 90%, noncondensing |
| Storage | 5% to 95%, noncondensing |
| Pollution degree | 2 |
| Maximum altitude | 2,000 m (800 mbar) (at 25 °C ambient temperature) |
| Operating vibration | 5 Hz to 500 Hz, 0.3 g RMS |
| Non-operating vibration | 5 Hz to 500 Hz, 2.4 g RMS |
| Operating shock | 30 g, half-sine, 11 ms pulse |
官方规格书:https://www.ni.com/docs/en-US/bundle/pxie-4150-specs/page/specs.html
NI官方渠道
官方渠道(官网 / 热线 / 邮箱)
官方渠道(中国大陆)
• 官网 www.ni.com/zh-cn
• 在线选购 www.ni.com/zh-cn/shop.html
• 经销商查询
官网「查找经销商」 www.ni.com/zh-cn/shop/advisors.html
• 联系方式
NI 中文官网不公布中国区电话与邮箱,报价、技术支持、校准、维修一律通过官网在线表单提交(「联系我们」页)
全国办事处
公司总部
• NI(National Instruments)
• 地址
11500 N Mopac Expwy, Austin, TX 78759-3504, United States
• 母公司
Emerson(2023 年完成收购,NI 隶属艾默生测试与测量业务集团)
0条提问