最大电流:75 A
总输出功率:750 瓦
机架高度:1U
机架宽度:全宽
750 W,0 VDC ~ 30 VDC,0 A ~ 75 A可编程电源设备
ONETEST 欢迎您
厂商登录 | 入驻
登录 | 注册 购物车 微信公众号厂商登录
最大电流:75 A
总输出功率:750 瓦
机架高度:1U
机架宽度:全宽
750 W,0 VDC ~ 30 VDC,0 A ~ 75 A可编程电源设备
以下指标取自 Teledyne 官方在线规格书,按原文档小节分组。
| 372711A-01 | July 2026 |
| 375744E-01 | November 2024 |
| Nominal input rating | 100 V AC to 240 V AC, 50 to 60 Hz, single phase |
| Input voltage range | 85 V AC to 265 V AC |
| Input frequency | 47 Hz to 63 Hz |
| Inrush current (maximum)[1] | 70 A peak or less |
| Power (maximum) | 1100 VA (for all loads, with 100 VAC input) |
| Power factor (TYP) (with the rated load) | 0.99 (input voltage: 100 V) 0.97 (input voltage: 200 V) |
| Efficiency (minimum) (with the rated load) | 74% or more |
| Hold-up time for power interruption (minimum) | 20 ms or greater (for all loads, with 100 V AC input) |
| 100 V AC | 10.5 A |
| 200 V AC | 5.25 A |
| RMX-4120 | 30 V |
| RMX-4121 | 80 V |
| RMX-4122 | 230 V |
| RMX-4123 | 650 V |
| RMX-4120 | 75 A |
| RMX-4121 | 28 A |
| RMX-4122 | 10 A |
| RMX-4123 | 3.5 A |
| Output power | 750 W |
| RMX-4120 | 0 V to 31.5 V |
| RMX-4121 | 0 V to 84 V |
| RMX-4122 | 0 V to 241.5 V |
| RMX-4123 | 0 V to 682.5 V |
| Setting accuracy | ±(0.05% of setting + 0.05% of rtg) |
| RMX-4120 | ±5 mV |
| RMX-4121 | ±10 mV |
| RMX-4122 | ±25 mV |
| RMX-4123 | ±67 mV |
| RMX-4120 | ±5 mV |
| RMX-4121 | ±10 mV |
| RMX-4122 | ±25 mV |
| RMX-4123 | ±67 mV |
| RMX-4120/4121 | 1 ms or less |
| RMX-4122/4123 | 7 ms or less |
| RMX-4120 | 60 mV |
| RMX-4121 | 80 mV |
| RMX-4122 | 120 mV |
| RMX-4123 | 330 mV |
| RMX-4120/4121 | 8 mV |
| RMX-4122 | 25 mV |
| RMX-4123 | 60 mV |
| Rated load | 100 ms |
| No load | 100 ms |
| RMX-4120/4121 | 100 ms |
| RMX-4122 | 150 ms |
| RMX-4123 | 250 ms |
| RMX-4120 | 1.5 V |
| RMX-4121 | 4 V |
| RMX-4122/4123 | 5 V |
| Temperature coefficient (maximum) | 100 ppm/°C (during external control) |
| Maximum display, RMX-4120/4121 | 99.99 (fixed decimal point) |
| Maximum display, RMX-4122/4123 | 999.9 (fixed decimal point) |
| Display accuracy | ±(0.2% of rdg +5 digits) |
| Maximum display, RMX-4120/4121/4122 | 99.99 (fixed decimal point) |
| Maximum display, RMX-4123 | 999.9 (fixed decimal point) |
| Display accuracy | ±(0.5% of reading +5 digits) |
| Power display behavior | PWR DSPL key lights red Press PWR DSPL to display the power on the ammeter. Each time you press this key, the display switches between power and current. |
| Maximum display | 9999 |
| Green | Output on |
| Off | Output off |
| Blinking orange | The output is on and a protection function has been activated |
| CV operation | CV LED lights green |
| CC operation | CC LED lights red |
| Red | A protection function has been activated |
| Blinking red | The power limit (POWER LIMIT) has been activated |
| Preset memory | The PRESET A, B, or C LED lights green when a preset memory entry is being used |
| Key lock operation | LOCK LED lights green when the keys are locked |
| Remote operation | REMOTE LED lights green during remote control |
| Green | No fault status |
| Blinking green | WEB identify status |
| Red | Fault status |
| Orange | Standby status |
| Overvoltage protection (OVP) behavior | Turns the output off, displays OVP, and lights ALARM |
| Setting accuracy | ±(1.5% of rtg) |
| RMX-4120 | 3 V to 33.6 V |
| RMX-4121 | 8 V to 89.6 V |
| RMX-4122 | 23 V to 257.6 V |
| RMX-4123 | 65 V to 728.0 V |
| Overvoltage protection 2 (OVP2) behavior | Turns the output off, displays OVP2, and lights ALARM |
| RMX-4120 | 36 V (120% of the rated output voltage) |
| RMX-4121 | 96 V (120% of the rated output voltage) |
| RMX-4122 | 276 V (120% of the rated output voltage) |
| RMX-4123 | 780 V (120% of the rated output voltage) |
| Overcurrent protection (OCP) behavior | Turns the output off, displays OCP, and lights ALARM |
| Setting accuracy | ±(3% of rtg) |
| RMX-4120 | 7.5 A to 84 A |
| RMX-4121 | 2.8 A to 31.36 A |
| RMX-4122 | 1 A to 11.2 A |
| RMX-4123 | 0.35 A to 3.92 A |
| Undervoltage limit (UVL) (OVP2) behavior | Output voltage cannot be set to a value less than or equal to the UVL voltage |
| RMX-4120 | 0 V to 31.5 V |
| RMX-4121 | 0 V to 84 V |
| RMX-4122 | 0 V to 241.5 V |
| RMX-4123 | 0 V to 682.5 V |
| Overheat protection (OHP) behavor | Turns the output off, displays OHP, and lights ALARM |
| Overheat protection2 (OHP2) behavior | Turns the output off, displays OHP2, and lights ALARM |
| Fan failure protection (FAN) behavior | Turns the output off, displays FAN, and lights ALARM |
| Incorrect sensing connection protection (SENSE) behavior | Turns the output off, displays SENS, and lights ALARM |
| Low AC input protection (AC-FAIL) behavior | Turns the output off, displays AC, and lights ALARM |
| Shutdown (SD) behavior | Turns the output off, displays SD, and lights ALARM |
| Power limit (POWER LIMIT) behavior | Blinks ALARM |
| Power limit (POWER LIMIT) value (fixed) | 787.5 (approximately 105% of the rated output power) |
| Communication monitoring (WATCHDOG) behavior | Turns the output off, displays DOG, and lights ALARM |
| Voltage monitor (VMON) selectable monitor voltage range | 0 V to 5 V or 0 V to 10 V |
| Voltage monitor (VMON) setting accuracy | 2.5% of rtg |
| Current monitor (IMON) selectable monitor voltage range | 0 V to 5 V or 0 V to 10 V |
| Current monitor (IMON) setting accuracy | 2.5% of rtg |
| OUTON STATUS | Turns on when the output is on |
| CV STATUS | Turns on during CV operation |
| CC STATUS | Turns on during CC operation |
| ALM STATUS | Turns on when an alarm has been activated |
| PWR ON STATUS | Turns on when the power is turned on |
| Output voltage control (VPGM) | 0% to 100% of the rated output voltage. |
| Output voltage control (VPGM) selectable control voltage range | 0 V to 5 V or 0 to 10 V |
| Output voltage control (VPGM) accuracy | 5% of rtg |
| Output current control (IPGM) | 0% to 100% of the rated output current. |
| Output current control (IPGM) selectable control voltage range | 0 V to 5 V or 0 to 10 V |
| Output current control (IPGM) accuracy | 5% of rtg |
| Output on/off control OUTPUT ON/OFF CONT | Possible logic selections: Turn the output on using a LOW (0 V to 0.5 V) or short-circuit, turn the output off using a HIGH (4.5 V to 5 V) or open-circuit. Turn the output on using a HIGH (4.5 V to 5 V) or open-circuit, turn the output off using a LOW (0 V to 0.5 V) or short-circuit. |
| Output shutdown control SHUT DOWN | Turns the output off with a LOW (0 V to 0.5 V) or short-circuit |
| Alarm clear control ALM CLR | Clears alarms with a LOW (0 V to 0.5 V) or short-circuit. |
| RMX-4120/4121/4122 master-slave parallel operation | Including the master unit, up to four units (all the same model) can be connected (not supported on the RMX-4123) |
| RMX-4120/4121/4122 series operation | Up to two units (all the same model) can be connected (not supported on the RMX-4123) |
| Preset memory | Up to three sets of the following settings can be saved: the set voltage, the set current, the set OVP, the set OCP, and the set UVL |
| Key lock | Locks the operation of all keys other than the OUTPUT key |
| Between master unit and PC | LAN, USB, RS232C |
| Slave unit | LAN |
| Software protocol | IEEE Std 488.2-1992 |
| Hardware | Complies with the EIA232D specifications (excluding the connector) |
| Hardware connector | RJ-45 connector (Category 5; use a straight cable) |
| Hardware baud rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps |
| Hardware data length | 8 bits Stop bits: 1 bit |
| Hardware parity bit | None |
| Hardware flow control | No flow control |
| Program message terminator | LF during reception, CR/LF during transmission |
| Hardware | Complies with the USB 2.0 specifications. |
| Hardware baud rate | 480 Mbps (high speed) |
| Hardware socket | Socket B type |
| Program message terminator | LF or EOM during reception, LF + EOM during transmission |
| Device class | Complies with the USBTMC-USB488 device class specifications |
| Hardware | IEEE 802.3 100Base-TX or 10Base-T Ethernet IPv4 |
| Hardware connector | RJ-45 connector (Category 5; use a straight cable) |
| Communication protocol | VXI-11, HiSLIP, or SCPI-RAW |
| Program message terminator | VXI-11 and HiSLIP: LF or END during reception, LF + END during transmission SCPI-RAW: LF during reception, LF during transmission |
| RMX-4120/4121 | Approximately 8 kg (17.64 lb) |
| RMX-4122/4123 | Approximately 7.5 kg (16.53 lb) |
| Cooling method | Forced air cooling using fan |
| Operating environment | Indoor use, overvoltage category II |
| Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
| Operating humidity | 20 to 85% rh (no condensation) |
| Storage temperature | -10° to 60° C (14° to 140° F) |
| Storage humidity | 90% rh or less (no condensation) |
| Altitude | Up to 2,000 m |
| Pollution Degree | 2 |
| Grounding polarity | Negative grounding or positive grounding possible (Confirm the RMX-4123 is not grounded when it generates greater than 600 V.) |
| RMX-4120/4121 | ±250 Vmax |
| RMX-4122 | ±500 Vmax |
| RMX-4123 | ±600 Vmax |
| Between input and FG | No abnormalities at 1500 VAC for 1 minute |
| Between input and output, RMX-4120/4121/4122 | No abnormalities at 2000 VAC for 1 minute |
| Between input and output, RMX-4123 | No abnormalities at 2250 VAC for 1 minute |
| Between output and FG, RMX-4120/4121 | No abnormalities at 1500 VDC for 1 minute |
| Between output and FG, RMX-4122 | No abnormalities at 1600 VDC for 1 minute |
| Between output and FG, RMX-4123 | No abnormalities at 2000 VDC for 1 minute |
| Between input and FG | ±500 Vdc, 100 MΩ or more (70% or less) |
| Between input and output, RMX-4120/4121/4122 | ±500 VDC, 100 MΩ or more (70% or less) |
| Between input and output, RMX-4123 | ±1000 VDC, 100 MΩ or more (70% or less) |
| Between output and FG, RMX-4120/4121/4122 | ±500 VDC, 40 MΩ or more (70% or less) |
| Between output and FG, RMX-4123 | ±1000 VDC, 40 MΩ or more (70% or less) |
官方规格书:https://www.ni.com/docs/en-US/bundle/rmx-4120-4121-4122-4123-specs/page/specs.html
NI官方渠道
官方渠道(官网 / 热线 / 邮箱)
官方渠道(中国大陆)
• 官网 www.ni.com/zh-cn
• 在线选购 www.ni.com/zh-cn/shop.html
• 经销商查询
官网「查找经销商」 www.ni.com/zh-cn/shop/advisors.html
• 联系方式
NI 中文官网不公布中国区电话与邮箱,报价、技术支持、校准、维修一律通过官网在线表单提交(「联系我们」页)
全国办事处
公司总部
• NI(National Instruments)
• 地址
11500 N Mopac Expwy, Austin, TX 78759-3504, United States
• 母公司
Emerson(2023 年完成收购,NI 隶属艾默生测试与测量业务集团)
0条提问
X
提问
X
回答
发表口碑
AI问答