总线连接:PXI混合
模拟输入阻抗:50 欧姆
示波器最大带宽:6 MHz
电压输入通道数量:2
24位灵活分辨率PXI示波器
ONETEST 欢迎您
厂商登录 | 入驻
登录 | 注册 购物车 微信公众号厂商登录
总线连接:PXI混合
模拟输入阻抗:50 欧姆
示波器最大带宽:6 MHz
电压输入通道数量:2
24位灵活分辨率PXI示波器
以下指标取自 Teledyne 官方在线规格书,按原文档小节分组。
| CH 0, CH 1 | Standard BNC connector |
| TRIG | Standard BNC connector |
| CLK IN | SMB jack |
| CLK OUT | SMB jack |
| AUX I/O | 9-pin mini-circular DIN connector |
| 1 | 5 V (Fused) |
| 2 | GND |
| 3 | Reserved |
| 4 | Reserved |
| 5 | Reserved |
| 6 | PFI 1 |
| 7 | Reserved |
| 8 | Reserved |
| 9 | PFI 0 |
| Number of channels | Software-selectable: two simultaneously sampling, single-ended or unbalanced differential channels or one differential channel |
| Connector | BNC |
| Input impedance | Software-selectable: 50 Ω ±2.0% or 1 MΩ ±2.0% in parallel with a nominal capacitance of 60 pF |
| Input coupling | AC, DC, GND |
| Full-scale (FS) input range | ±1 V (2 Vpk-pk) ±5 V (10 Vpk-pk) |
| Maximum input overload 50 Ω 7 V RMS with |Peaks| ≤10 V 1 MΩ |Peaks| ≤42 V | 50 Ω |
| 50 Ω | 7 V RMS with |Peaks| ≤10 V |
| 1 MΩ | |Peaks| ≤42 V |
| 50 kS/s | 24 bits |
| 500 kS/s | 24 bits |
| 1 MS/s | 22 bits |
| 5 MS/s | 20 bits |
| 10 MS/s | 18 bits |
| 15 MS/s | 16 bits |
| DC accuracy[1] 2 Vpk-pk range ±(0.05% of input + 50 μV), warranted 10 Vpk-pk range ±(0.05% of input + 100 μV), warranted | 2 Vpk-pk range |
| 2 Vpk-pk range | ±(0.05% of input + 50 μV), warranted |
| 10 Vpk-pk range | ±(0.05% of input + 100 μV), warranted |
| DC drift[2] 2 Vpk-pk range ±(0.002% of input + 5 μV per °C), nominal 10 Vpk-pk range ±(0.002% of input + 10 μV per °C), nominal | 2 Vpk-pk range |
| 2 Vpk-pk range | ±(0.002% of input + 5 μV per °C), nominal |
| 10 Vpk-pk range | ±(0.002% of input + 10 μV per °C), nominal |
| AC amplitude accuracy | 0.06% at 1 kHz[3] |
| Crosstalk[4] At 100 kHz ≤-110 dB At 1 MHz ≤-100 dB At 6 MHz ≤-80 dB | At 100 kHz |
| At 100 kHz | ≤-110 dB |
| At 1 MHz | ≤-100 dB |
| At 6 MHz | ≤-80 dB |
| Common-mode rejection ratio (CMRR) | 50 dB up to 1 kHz[5] |
| Alias-free bandwidth | 0.4 × Sample Rate |
| <5 MS/s | 100 dB |
| 5 MS/s | 96 dB |
| (5 MS/s, 7.5 MS/s) | 90 dB |
| [7.5 MS/s, 15 MS/s] | 80 dB |
| AC coupling cutoff (-3 dB) | 90 Hz |
| 1 MS/s | 0.03 dB |
| 5 MS/s | 0.06 dB |
| 10 MS/s | 0.15 dB |
| 15 MS/s | 0.3 dB |
| 10 kHz | 114 dBc |
| 100 kHz | 110 dBc |
| 1 MHz | 96 dBc |
| 10 kHz | -112 dBc |
| 100 kHz | -108 dBc |
| 1 MHz | -94 dBc |
| 1 MS/s | 105 dB |
| 10 MS/s | 89 dB |
| 1 MS/s | 108 dB |
| 10 MS/s | 91 dB |
| 50 kS/s | -120 |
| 100 kS/s | -118 |
| 1 MS/s | -108 |
| 5 MS/s | -101 |
| 10 MS/s | -91 |
| 15 MS/s | -79 |
| Channel-to-channel skew[14] | ≤500 ps |
| Input bias current[15] | ≤500 nA, warranted |
| 48 Tap Standard | 800 ns |
| 48 Tap Hanning | 700 ns |
| 16 Tap Hanning | 300 ns |
| 8 Tap Hanning | 200 ns |
| Sample rate range, real-time sampling (single shot)[20] | 50 kS/s to 15 MS/s |
| Phase noise density (5 MHz input signal) At 10 kHz <-133 dBc/Hz At 100 kHz <-145 dBc/Hz | At 10 kHz |
| At 10 kHz | <-133 dBc/Hz |
| At 100 kHz | <-145 dBc/Hz |
| Sample clock jitter[21] | ≤3 ps RMS (100 Hz to 1 MHz) |
| Timebase frequency | 120 MHz |
| Timebase accuracy Not phase-locked to Reference clock ±50 ppm, warranted Phase-locked to Reference clock Equal to the Reference clock accuracy | Not phase-locked to Reference clock |
| Not phase-locked to Reference clock | ±50 ppm, warranted |
| Phase-locked to Reference clock | Equal to the Reference clock accuracy |
| Sample clock delay range | ±1 Sample clock period |
| Sample clock delay resolution | 400 ps |
| Reference clock sources | PXI_CLK 10 (backplane connector) CLK IN (front panel SMB connector) |
| Frequency range | 1 MHz to 20 MHz in 1 MHz increments[22]; must be accurate to ±50 ppm |
| Duty cycle tolerance | 45% to 55% |
| Exported Reference clock destinations | CLK OUT (front panel SMB connector) PFI <0..1> (front panel 9-pinmini-circular DIN connector) PXI_TRIG <0..6> (backplane connector) |
| Input voltage range | Square wave: 0.2 Vpk-pk to 1 Vpk-pk |
| Maximum input overload | 7 V RMS with |Peaks| ≤10 V |
| Impedance | 50 Ω |
| Coupling | AC |
| Output impedance | 50 Ω |
| Logic type | 5 V CMOS |
| Maximum drive current | ±50 mA |
| Trigger types | Edge Window Hysteresis Digital Immediate Software |
| Trigger sources | CH 0 CH 1 TRIG PXI_Trig <0..6> PFI <0..1> PXI Star Trigger RTSI <0..6> Software |
| Time resolution | Sample clock period |
| Rearm time | 144 × Sample clock period[23] |
| Holdoff | Up to (232 - 1) × Sample clock period |
| Trigger types | Edge Window Hysteresis |
| Sources[24] | CH 0 (front panel BNC connector) CH 1 (front panel BNC connector) TRIG (front panel BNC connector) |
| Trigger level range | 100% FS |
| Edge trigger sensitivity CH 0, CH 1 2% FS TRIG (external trigger) 0.3 Vpk-pk up to 1 MHz | CH 0, CH 1 |
| CH 0, CH 1 | 2% FS |
| TRIG (external trigger) | 0.3 Vpk-pk up to 1 MHz |
| Jitter | Sample clock period |
| Trigger type | Digital |
| Sources | PXI_TRIG <0..6> (backplane connector) PFI <0..1> (front panel 9-pin DIN connector PXI Star Trigger (backplane connector) |
| Source | TRIG (front panel BNC connector) |
| Impedance | 100 kΩ in parallel with 52 pF, nominal |
| Input voltage range | ±2.5 V |
| Coupling | DC |
| Level accuracy | ±0.3 V up to 100 kHz |
| Maximum input overload | |Peaks| ≤42 V |
| Connector | 9-pin mini-circular DIN |
| Direction | Bidirectional |
| Destinations | Start trigger (acquisition arm) Reference (stop) trigger Arm Reference trigger Advance trigger |
| Input impedance | 150 kΩ , nominal |
| VIH | 2.0 V |
| VIL | 0.8 V |
| Maximum input overload | -0.5 V, 5.5 V |
| Maximum frequency | 25 MHz |
| Sources | Start trigger (acquisition arm) Reference (stop) trigger End of Record Done (end of acquisition) |
| Output impedance | 50 Ω |
| Logic type | 3.3 V CMOS |
| Maximum drive current | ±24 mA |
| Maximum frequency | 20 MHz |
| Onboard memory size 8 MB/channel 2 MS/channel 32 MB/channel 8 MS/channel 256 MB/channel 64 MS/channel | 8 MB/channel |
| 8 MB/channel | 2 MS/channel |
| 32 MB/channel | 8 MS/channel |
| 256 MB/channel | 64 MS/channel |
| Minimum record length | 1 Sample |
| Number of pretrigger samples | 0 up to full Record Length for both single-record mode and multiple-record mode |
| Number of posttrigger samples | 0 up to full Record Length for both single-record mode and multiple-record mode |
| Maximum number of records in onboard memory[25] 8 MB/channel 13,107 32 MB/channel 52,428 256 MB/channel 100,000 | 8 MB/channel |
| 8 MB/channel | 13,107 |
| 32 MB/channel | 52,428 |
| 256 MB/channel | 100,000 |
| Allocated onboard memory per record | (Record Length × 4 bytes/S) + 400 bytes, rounded up to next multiple of 128 bytes or 640 bytes, whichever is greater |
| Self-calibration | Self-calibration is done on software command. The calibration corrects for gain and offset for all input ranges, input bias current, and nonlinearities in the ADCs. |
| External calibration (factory calibration) | The external calibration calibrates the VCXO and the voltage reference. Appropriate constants are stored in nonvolatile memory. |
| Interval for external calibration | 2 years |
| Warm-up time | 15 minutes |
| Skew[26] | 500 ps |
| Average skew after manual adjustment | <10 ps |
| Sample clock delay/adjustment resolution | ≤5 ps |
| Current draw +3.3 V DC 2.0 A +5 V DC 1.4 A +12 V DC 330 mA -12 V DC 280 mA | +3.3 V DC |
| +3.3 V DC | 2.0 A |
| +5 V DC | 1.4 A |
| +12 V DC | 330 mA |
| -12 V DC | 280 mA |
| Total power | 20.9 W |
| Dimensions | 3U, one-slot, PXI/cPCI module 21.6 cm × 2.0 cm × 13.0 cm (8.5 in × 0.8 in × 5.1 in) |
| Weight | 336 g (11.8 oz) |
| Maximum altitude | 2,000 m (at 25 °C ambient temperature) |
| Pollution degree | 2 |
| Ambient temperature range | 0 °C to 55 °C in all NI PXI chassis except the following: 0 °C to +45 °C when installed in an NI PXI-1000/B or PXI-101x chassis. (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) |
| Relative humidity range | 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
| Ambient temperature range | -40 °C to 71 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) |
| Relative humidity range | 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
| Operational shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) |
| Storage Shock | 50 g, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27.Test profile developed in accordance with MIL-PRF-28800F.) |
| Random vibration Operating 5 Hz to 500 Hz, 0.31 grms (Tested in accordance with IEC 60068-2-64.) Nonoperating 5 Hz to 500 Hz, 2.46 grms (Tested in accordance with IEC 60068-2-64. Test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) | Operating |
| Operating | 5 Hz to 500 Hz, 0.31 grms (Tested in accordance with IEC 60068-2-64.) |
| Nonoperating | 5 Hz to 500 Hz, 2.46 grms (Tested in accordance with IEC 60068-2-64. Test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) |
官方规格书:https://www.ni.com/docs/en-US/bundle/pxi-5922-specs/page/specs.html
NI官方渠道
官方渠道(官网 / 热线 / 邮箱)
官方渠道(中国大陆)
• 官网 www.ni.com/zh-cn
• 在线选购 www.ni.com/zh-cn/shop.html
• 经销商查询
官网「查找经销商」 www.ni.com/zh-cn/shop/advisors.html
• 联系方式
NI 中文官网不公布中国区电话与邮箱,报价、技术支持、校准、维修一律通过官网在线表单提交(「联系我们」页)
全国办事处
公司总部
• NI(National Instruments)
• 地址
11500 N Mopac Expwy, Austin, TX 78759-3504, United States
• 母公司
Emerson(2023 年完成收购,NI 隶属艾默生测试与测量业务集团)
0条提问
X
提问
X
回答
发表口碑
AI问答