ONETEST 欢迎您

厂商登录 | 入驻

登录 | 注册 购物车 微信公众号
请完成安全验证

类似产品

在3U机箱内提供20kW额定输出;电压量程覆盖500V、1000V、1500V三档可选三相三线200V或400V输入系列采用2.25至3倍功率比的功率型工作区设计额定功率内电压与电流可大范围组合(PXT20K-500可从500V-40A运行到166.6V-120A)50°C环境温度下满载连续运行标配LAN、USB、RS232C与隔离型外部模拟控制并具备可变内阻、Bleeder通断、序列、I-V特性等功能最多25台并联可扩展至500kW

同厂商产品

TC-1P-12 是松田精密(Matsusada Precision)TC 系列的一款直流电源,最大输出电压 1V,最大输出电流 1.5mA
TC-1.5P-15 是松田精密(Matsusada Precision)TC 系列的一款直流电源,最大输出电压 1.5V,最大输出电流 1mA
TC-1.5P-12 是松田精密(Matsusada Precision)TC 系列的一款直流电源,最大输出电压 1.5V,最大输出电流 1mA
  • «
  • 1

TB850V3.6A1080W 850V/3.6A直流电源 1.08kW|松田精密 (在产)

TB850V3.6A1080W 是松田精密(Matsusada Precision)TB 系列的一款直流电源,最大输出电压 850V,最大输出电流 3.6A,最大输出功率 1.08kW

参考价格 :
产品描述
详细指标
软件和手册|白皮书
购买渠道
选件
问大家
视频
测评
口碑
系统与解决方案

松田精密|Matsusada Precision Inc.
TB850V3.6A1080W 直流电源
VERSATILE 直流直流电源 850V / 3.6A / 1.08kW
产品简介
TB850V3.6A1080W 是松田精密(Matsusada Precision)TB 系列的一款直流电源,最大输出电压 850V,最大输出电流 3.6A,最大输出功率 1.08kW。 The TB series is a programmable DC power supply featuring a unique "Turbo Function" that provides a voltage and current coverage area three times wider than conventional DC power supplies of equivalent power rating. All TB series models allow flexible voltage and current output within their rated power, eliminating the need to select different power supplies for varying requirements. A single TB unit supports a wide range of applications. In addition to its wide output range, the TB series is engineered for exceptional performance. It features a power factor correction (PFC) circuit with a factor of 0.99, a fast and accurate four-digit display, and a precision rotary encoder. Its high energy efficiency also contributes to reducing CO 2 emissions.
核心参数
• 最大输出电压:850 V
• 电流:3.6 A
• 功率:1080 W
• Ripple * 1 / Voltage:45 mVrms
• 电流:15 mArms
• 输入电压:100 to 240 Vac, 50/60 Hz, Single-phase
• 输出电压控制:[Local] Rotary encoder on front panel [Analog remote] External control voltage 0 to 10 Vdc or external 10kΩ potentiometer [Digital remote] Command
• 输出电流控制:[Local] Rotary encoder on front panel [Analog remote] External control voltage 0 to 10 Vdc or external 10kΩ potentiometer [Digital remote] Command
• -LEt *1:LAN Interface Port Enables digital control via LAN. For controlling multiple TB units: A hub is required between the computer and the TB units, OR Units can be daisy-chained. (The first unit requires the -LEt option, while subsequent units use the standard digital interface.)
• -LFs:Pause air-cooling fan The air cooling fan of the power supply can be stopped for 1.0 seconds to 120.0 seconds. The time to stop can be arbitrarily set in 0.1-second increments on the front panel. (Depending on the usage conditions, the output may be turned off by the protective function of the main unit. When using the -LFs option with Pulse & Ramp Sequence or Delayed trigger , use within the range which the cooling fan stop time is not exceeded. If the cooling fan stop time is exceeded, the output will stop.)
• -LGob *1:Optical interface port This option changes the standard interfaces to a built-in optical interface port. By combining this option with an adapter for optical connection (sold separately), communication between the control device and the power supply can be controlled in an isolated state. Be sure to select this option when using the product in the following environments. -LGob: Optical interface board + optical cable 2 meters -LGob(Fc5): Optical interface board + optical cable 5 meters -LGob(Fc10): Optical interface board + optical cable 10 meters -LGob(Fc20): Optical interface board + optical cable 20 meters -LGob(Fc40): Optical interface board + optical cable 40 meters Select the optional optical interface port (-LGob) when using this DC power supply under the following conditions. Noisy environments such as factories (example: when motors or coils are used near loads or power sources). If this power supply and your controller (PC or PLC) cannot be installed within 2 meters. When there is a possibility of arcing or output short-circuit. * Adapter (CO/USB series) is required separately for control via digital interface. If you select the -LEt or -LUs1 option, no adapter is required.
• -LIc:Output current accumulation function Accumulate the output current and display its value (up to +9999.999 Ah). The accumulated value is stored even when the output is off. Because the accumulated value that stops the output can be set preliminarily, it is very suitable for applications such as controlling plating solutions. (Please consider the location of usage. High humidity environment can be the cause of failure and corrosion.)
功能特性
• Images of Output Range:With the turbo function, a wide range of voltage and current output compared with conventional DC power supplies. 35 V models 250 V models 1000 V models
• 脉冲, Ramp, and Master Follow Functions:The following output control modes (A to D) are available to meet various testing requirements.
• A. 脉冲 (Step) Sequence Function:The Sequence function lets you generate complex voltage and current patterns by automatically cycling through settings stored in memories a, b, and c. You can run the sequence continuously or for a specified number of cycles. By setting the duration of any step (a, b, c, or off) to 0.0, you can easily skip steps to create custom test patterns. This flexibility is ideal for product evaluation and r
• B. 斜坡函数:The Ramp function provides linear control to gradually increase the output to a set voltage/current, or decrease it to zero. This feature is useful for applications that require a slow power-up or power-down. * The ramp operation can be applied to: Voltage and Current, Voltage Only, or Current Only. t1 and t2 can be set respectively in 0.0s to 999.9s.
• C. 组合序列与斜坡:For advanced control, the Sequence and Ramp functions can be used together. This allows you to create complex profiles by smoothly ramping the voltage and/or current between the discrete steps defined in memories a, b, and c. The entire waveform can be run continuously or for a pre-set number of cycles, making it a powerful tool for various testing scenarios. t1 and t2 can be set from 0.0 s to 999
• D. Master Follow (Tracking):Master-follow is a function that allows a slave equipment to follow the output status of the master equipment in a master/slave connection. The output status of the master equipment is transmitted to the slave equipments to enable interlocked operation. The master and slave can be set to different modes of operation, allowing for complex testing. * The Master Follow function is available only with
• Variable Internal Resistance Function (in CV mode):By setting the internal resistance value as any value, it causes a voltage drop due to load current. This is the best fit for simulating batteries, solar cells/panels, and fuel cells. (Programmable range of the internal resistance value is 0 Ω to rated voltage/rated current) Example
• Function for Multi-setting:Three sets of voltage and current values can be stored in memory, in addition to the standard preset. This is highly useful for experiments requiring repeated data collection and product inspection.
资源下载
以上内容与指标均取自Matsusada Precision 官网产品页与官方数据手册,未标注口径的为厂家公布值。
松田精密(Matsusada Precision) · onetest 仪器资源库

 

 

松田精密|Matsusada Precision Inc.
TB850V3.6A1080W 直流电源 详细指标
VERSATILE 直流直流电源 850V / 3.6A / 1.08kW
详细指标
以下指标取自松田精密(Matsusada Precision)官网 TB 系列产品页的「Models / Specifications / Options / Dimensions」区块,其中「型号输出参数」为该型号在官方型号表中的原始列值;官方原文为英文,此处按原文保留。详细规格与测试条件以官方数据手册为准。
型号输出参数
• 最大输出电压:850 V
• 电流:3.6 A
• 功率:1080 W
• Ripple * 1 / Voltage:45 mVrms
• 电流:15 mArms
系列共用规格
• 输入电压:100 to 240 Vac, 50/60 Hz, Single-phase
• 输出电压控制:[Local] Rotary encoder on front panel [Analog remote] External control voltage 0 to 10 Vdc or external 10kΩ potentiometer [Digital remote] Command
• 输出电流控制:[Local] Rotary encoder on front panel [Analog remote] External control voltage 0 to 10 Vdc or external 10kΩ potentiometer [Digital remote] Command
• -LEt *1:LAN Interface Port Enables digital control via LAN. For controlling multiple TB units: A hub is required between the computer and the TB units, OR Units can be daisy-chained. (The first unit requires the -LEt option, while subsequent units use the standard digital interface.)
• -LFs:Pause air-cooling fan The air cooling fan of the power supply can be stopped for 1.0 seconds to 120.0 seconds. The time to stop can be arbitrarily set in 0.1-second increments on the front panel. (Depending on the usage conditions, the output may be turned off by the protective function of the main unit. When using the -LFs option with Pulse & Ramp Sequence or Delayed trigger , use within the range which the cooling fan stop time is not exceeded. If the cooling fan stop time is exceeded, the output will stop.)
• -LGob *1:Optical interface port This option changes the standard interfaces to a built-in optical interface port. By combining this option with an adapter for optical connection (sold separately), communication between the control device and the power supply can be controlled in an isolated state. Be sure to select this option when using the product in the following environments. -LGob: Optical interface board + optical cable 2 meters -LGob(Fc5): Optical interface board + optical cable 5 meters -LGob(Fc10): Optical interface board + optical cable 10 meters -LGob(Fc20): Optical interface board + optical cable 20 meters -LGob(Fc40): Optical interface board + optical cable 40 meters Select the optional optical interface port (-LGob) when using this DC power supply under the following conditions. Noisy environments such as factories (example: when motors or coils are used near loads or power sources). If this power supply and your controller (PC or PLC) cannot be installed within 2 meters. When there is a possibility of arcing or output short-circuit. * Adapter (CO/USB series) is required separately for control via digital interface. If you select the -LEt or -LUs1 option, no adapter is required.
• -LIc:Output current accumulation function Accumulate the output current and display its value (up to +9999.999 Ah). The accumulated value is stored even when the output is off. Because the accumulated value that stops the output can be set preliminarily, it is very suitable for applications such as controlling plating solutions. (Please consider the location of usage. High humidity environment can be the cause of failure and corrosion.)
• -LMi *1:Multi-digital interface port coming soon (only for some models) For details, download the TB series datasheet. Digital control by LAN, USB (USBTMC), and RS-485 (Multidrop) is available. (These simultaneous uses are impossible. RS-485 supports half-duplex (2-wire) and full-duplex (4-wire) communication.) The option includes an IVI driver corresponding to the SCPI command. It makes it easy to control program development with various programming languages such as LabVIEW, Visual Basic, C#, etc.
• -LMs:Analog master-slave Up to 3 units (same model), including the master unit, can be operated in parallel using the remote connector. Users can control units using a remote control or a standard/optional digital interface for the master unit. (One control) Each parallel-connected unit power supply outputs equally. The master unit can display the whole system voltage and output. As the lead time for the models with this option differs from the standard one, be sure to contact our sales representative. [Optional items] Analog master/slave cable Model: TB-MS2 cable (to connect 2 units), TB-MS3 cable (to connect 3 units) It is a convenient connecting cable with connectors assembled. (If you select this option, you can make the same connecting cable even if you attach the attached parts yourselves.) The cable length between the connectors is 0.6 meters. If you would like to purchase this cable individually, consult your sales representative.
• -LUs1 *1:USB interface port Enable digital control via USB. When you want to control multiple TB models via LAN; Prepare/insert a hub between your computer and the TB model, or To connect all models serially, the first TB model is equipped with the LAN interface port, and the second and later equipped with a standard digital interface. OS for USB driver: Microsoft Windows Xp/Vista/7/8/10/11 (Both 32 bits and 64 bits are applicable) Microsoft and Windows are registered trademarks of Microsoft Corp. in the USA and others.
• -LZ:Handle for carrying The top panel has a handle for easy carrying, so the height of TB becomes higher. [added height] 360 W models: 0.31 inches (8 mm), 720 W models: 0.43 inches (11 mm), 1080 W models: 0.39 inches (10 mm)
• -L(Mc0.5)/-L(Mc0.15):Change Communication Cable Length The length of the CO-M cable is to be 0.5 meters and 0.15 meters respectively. (only either one is selectable.)
• Adapters for various digital interfaces (additional products):To use Matsusada Precision's digital interface,you need to prepare a digital interface adapter separately. The following interface adapters are available according to your controller port. CO-E32m:LAN adapter USB-MET/CO-U32m:USB adapter CO-MET2-9:RS-232C (9 pin) adapter CO-MET2-25:RS-232C (25 pin) adapter CO-MET4-25:RS-485 (25 pin) adapter CO-G32m:GPIB adapter (Scheduled for discontinuation in December 2028) Adapter for digital interface For details,refer to CO/USB series.
•Various 光学 interface adapters (additional products):To use the optical interface, you need to prepare an optical interface adapter separately. The following interface adapters are available according to your controller port. CO-E32: LAN to optical interface adapter USB-OPT: USB to optical interface adapter CO-OPT2-9: RS-232C (9 pin) to optical interface adapter CO-OPT2-25: RS-232C (25 pin) to optical interface adapter CO-OPT4-25: RS-485 (25 pin) to optical interface adapter CO-G32: GPIB to optical interface adapter (Scheduled for discontinuation in December 2028) Example of communication with optical fiber For details, refer to the CO/USB series.
•AC INPUT CABLE:Standard [360 W models] CABLE TYPE1 125 V/10 A 2.5 meters Fixed length Standard [720 W models] CABLE TYPE8 125 V/125 A 2.5 meters Fixed length Standard [1080 W models] CABLE TYPE5 300 V/25 A 2.5 meters Sold separately [360 W and 720 W models] CABLE TYPE3 250 V/10 A 2.5 meters Fixed length Sold separately [360 W and 720 W models] CABLE TYPE4 250 V/10 A 2.5 meters Fixed length Sold separately [1080 W models] CABLE TYPE2 125 V/15 A 2.5 meters Fixed length Please use the AC input cable suitable for the usage environment and the area. CABLE TYPE 3 and 4 correspond to CE marking.
•应用软件:PSS2en series: Remote control, Test workflow design, and Data logging PSS2en is the dedicated software that can control various power supplies, electronic loads, and digital controllers for power supplies manufactured by Matsusada Precision Inc. with a simple setup. It is perfect for the aging test, the burn-in test, and the withstand voltage test for electronic parts, as well as for the endurance test, intermittent/continuous operation test,or various simulation tests for automobile electric components. Click here for the PSS2en series
选件 / 附件
• -LEt *1:LAN Interface Port Enables digital control via LAN. For controlling multiple TB units:A hub is required between the computer and the TB units,OR Units can be daisy-chained. (The first unit requires the -LEt option,while subsequent units use the standard digital interface.)
•-LFs:Pause air-cooling fan The air cooling fan of the power supply can be stopped for 1.0 seconds to 120.0 seconds. The time to stop can be arbitrarily set in 0.1-second increments on the front panel. (Depending on the usage conditions, the output may be turned off by the protective function of the main unit. When using the -LFs option with Pulse & Ramp Sequence or Delayed trigger , use within the range which the cooling fan stop time is not exceeded. If the cooling fan stop time is exceeded, the output will stop.)
• -LGob *1:Optical interface port This option changes the standard interfaces to a built-in optical interface port. By combining this option with an adapter for optical connection (sold separately),communication between the control device and the power supply can be controlled in an isolated state. Be sure to select this option when using the product in the following environments. -LGob:Optical interface board + optical cable 2 meters -LGob(Fc5):Optical interface board + optical cable 5 meters -LGob(Fc10):Optical interface board + optical cable 10 meters -LGob(Fc20):Optical interface board + optical cable 20 meters -LGob(Fc40):Optical interface board + optical cable 40 meters Select the optional optical interface port (-LGob) when using this DC power supply under the following conditions. Noisy environments such as factories (example:when motors or coils are used near loads or power sources). If this power supply and your controller (PC or PLC) cannot be installed within 2 meters. When there is a possibility of arcing or output short-circuit. *Adapter (CO/USB series) is required separately for control via digital interface. If you select the -LEt or -LUs1 option,no adapter is required.
•-LIc:Output current accumulation function Accumulate the output current and display its value (up to +9999.999 Ah). The accumulated value is stored even when the output is off. Because the accumulated value that stops the output can be set preliminarily, it is very suitable for applications such as controlling plating solutions. (Please consider the location of usage. High humidity environment can be the cause of failure and corrosion.)
• -LMi *1:Multi-digital interface port coming soon (only for some models) For details,download the TB series datasheet. Digital control by LAN,USB (USBTMC),and RS-485 (Multidrop) is available. (These simultaneous uses are impossible. RS-485 supports half-duplex (2-wire) and full-duplex (4-wire) communication.) The option includes an IVI driver corresponding to the SCPI command. It makes it easy to control program development with various programming languages such as LabVIEW,Visual Basic,C#,etc.
•-LMs:Analog master-slave Up to 3 units (same model), including the master unit, can be operated in parallel using the remote connector. Users can control units using a remote control or a standard/optional digital interface for the master unit. (One control) Each parallel-connected unit power supply outputs equally. The master unit can display the whole system voltage and output. As the lead time for the models with this option differs from the standard one,be sure to contact our sales representative. [Optional items] Analog master/slave cable Model:TB-MS2 cable (to connect 2 units),TB-MS3 cable (to connect 3 units) It is a convenient connecting cable with connectors assembled. (If you select this option,you can make the same connecting cable even if you attach the attached parts yourselves.) The cable length between the connectors is 0.6 meters. If you would like to purchase this cable individually,consult your sales representative.
•-LUs1 *1:USB interface port Enable digital control via USB. When you want to control multiple TB models via LAN; Prepare/insert a hub between your computer and the TB model,or To connect all models serially,the first TB model is equipped with the LAN interface port,and the second and later equipped with a standard digital interface. OS for USB driver:Microsoft Windows Xp/Vista/7/8/10/11 (Both 32 bits and 64 bits are applicable) Microsoft and Windows are registered trademarks of Microsoft Corp. in the USA and others.
•-LZ:Handle for carrying The top panel has a handle for easy carrying, so the height of TB becomes higher. [added height] 360 W models: 0.31 inches (8 mm), 720 W models: 0.43 inches (11 mm), 1080 W models: 0.39 inches (10 mm)
• -L(Mc0.5)/-L(Mc0.15):Change Communication Cable Length The length of the CO-M cable is to be 0.5 meters and 0.15 meters respectively. (only either one is selectable.)
• Adapters for various digital interfaces (additional products):To use Matsusada Precision's digital interface, you need to prepare a digital interface adapter separately. The following interface adapters are available according to your controller port. CO-E32m: LAN adapter USB-MET/CO-U32m: USB adapter CO-MET2-9: RS-232C (9 pin) adapter CO-MET2-25: RS-232C (25 pin) adapter CO-MET4-25: RS-485 (25 pin) adapter CO-G32m: GPIB adapter (Scheduled for discontinuation in December 2028) Adapter for digital interface For details, refer to CO/USB series.
• Various 光学 interface adapters (additional products):To use the optical interface, you need to prepare an optical interface adapter separately. The following interface adapters are available according to your controller port. CO-E32: LAN to optical interface adapter USB-OPT: USB to optical interface adapter CO-OPT2-9: RS-232C (9 pin) to optical interface adapter CO-OPT2-25: RS-232C (25 pin) to optical interface adapter CO-OPT4-25: RS-485 (25 pin) to optical interface adapter CO-G32: GPIB to optical interface adapter (Scheduled for discontinuation in December 2028) Example of communication with optical fiber For details, refer to the CO/USB series.
• AC INPUT CABLE:Standard [360 W models] CABLE TYPE1 125 V/10 A 2.5 meters Fixed length Standard [720 W models] CABLE TYPE8 125 V/125 A 2.5 meters Fixed length Standard [1080 W models] CABLE TYPE5 300 V/25 A 2.5 meters Sold separately [360 W and 720 W models] CABLE TYPE3 250 V/10 A 2.5 meters Fixed length Sold separately [360 W and 720 W models] CABLE TYPE4 250 V/10 A 2.5 meters Fixed length Sold separately [1080 W models] CABLE TYPE2 125 V/15 A 2.5 meters Fixed length Please use the AC input cable suitable for the usage environment and the area. CABLE TYPE 3 and 4 correspond to CE marking.
• 应用软件:PSS2en series: Remote control, Test workflow design, and Data logging PSS2en is the dedicated software that can control various power supplies, electronic loads, and digital controllers for power supplies manufactured by Matsusada Precision Inc. with a simple setup. It is perfect for the aging test, the burn-in test, and the withstand voltage test for electronic parts, as well as for the endurance test, intermittent/continuous operation test, or various simulation tests for automobile electric components. Click here for the PSS2en series
资源下载
以上规格取自松田精密(Matsusada Precision)官网 TB 系列产品页(https://www.matsusada.com/product/dc-power-supplies/benchtop/tb/)。
松田精密(Matsusada Precision) · onetest 仪器资源库

全部

 

松田精密官方渠道


官方渠道(官网 / 热线 / 邮箱)


• 销售模式

Matsusada Precision Inc. 全球直销,不设授权代理商(官方 FAQ 明示 direct sales system)


• 全球咨询 +81-6-6150-5088


• 传真 +81-6-6150-5089


• 在线询价

https://www.matsusada.com/support/contact/


• 官网 https://www.matsusada.com/


全国办事处


美国办事处(北卡罗来纳)


• 电话 +1 (704) 496-2644


• 传真 +1 (704) 496-2643


 

0条提问

X

提问

X

回答

暂无视频

 

0条口碑
X

发表口碑

口碑标题
上传图片

ONETEST仪器资源库

联系电话:+86-755-23033660

电子邮箱:info@onetest.cn

Onetest仪器资源库

公众号

Onetest仪器资源库

视频号

Onetest仪器资源库

bilibili

Onetest仪器资源库

小助手

© 2026 Onetest仪器资源库 All Rights Reserved   粤ICP备17028186号-2      粤公网安备44030902003758