是德科技 | KEYSIGHT
941-0094 传输测试仪 详细指标
Test interconnects and emulate traffic up to 1.6T per port
Product description Interconnect and Network Performance Tester 800GE OSFP800
2-port and 4-port chassis models
Part numbers 941-0093 2-port OSFP800 benchtop chassis, 941-0094
4-port OSFP800 benchtop chassis
二、Hardware fixed chassis system Specifications
Number of ports
2-port OSFP800 benchtop chassis
4-port OSFP800 benchtop chassis
Physical interfaces Native OSFP800 physical front panel pluggable ports
Default speeds included with the chassis
• 1x800GE, 2x400GE, 4x200GE, and 8x100GE per port, PAM4 over
106Gb/s electrical lanes
• (Planned) 1x400GE, 2x200GE, 4x100GE, and 8x50GE, PAM4 over
53Gb/s electrical lanes
Optical transceiver and fiber cable interconnect support for all speeds
Active and passive copper cable interconnect support for all speeds
条件:• KP4 (RS-544, 514) Ethernet Forward Error Correction, IEEE 802.3 Clause 119:
Multicore processor with CPU memory per OSFP800 port per Ethernet speed
Number of users • 2 users on the
2-port chassis
• 4 users on the
4-port chassis
Interface protocols specifications for 800GE/106Gb/s electrical lane support
IEEE 802.3ck Physical Layer Specifications and Management Parameters for 100 Gb/s
200 Gb/s, and 400 Gb/s
Electrical Interfaces Based on
100 Gb/s Signaling
IEEE 802.3df-2024 Standard for Ethernet Amendment
9: Media Access Control Parameters for 800 Gb/s and
Physical Layers and Management Parameters for 400 Gb/s and 800 Gb/s Operation
Ethernet Technology Consortium
800 Gigabit Ethernet (GbE) v1.1 specification
(Planned) Interface protocols specifications for 400GE and 100GE for 53Gb/s electrical lane support
IEEE 802.3bs
200GE and 400GE
IEEE 802.3cd 50 Gb/s
100 Gb/s, and 200 Gb/s Ethernet
` 8
Product description Interconnect and Network Performance Tester 800GE OSFP800
2-port and 4-port chassis models
Layer 1 support
800GE PAM4 speeds for
106Gb/s electrical lanes
PAM4
800/400/200/100GE speeds:
• FEC symbol 误差 injection · 全部速度
• FEC Codeword symbol error correction distribution statistics
• Interleave FEC (RS-FEC-Int) for PAM4 100GE(ck) 100BASE-CR1 applications over
106Gb/s electrical lanes
• PCS Rx per lane and port statistics
• Layer
1 BERT with PRBS-7Q, PRBS-9Q, PRBS-11Q, PRBS-13Q, PRBS-15Q, PRBS-23Q, PRBS-31Q and SSPRQ
(Tx only) pattern generation support and Rx-side statistics and analysis. Additional test, pattern controls, per lane clock
ppm adjustment and pattern detection are included
• Layer
1 BERT with error injection
• BERT inferred FEC: The ability to run a BERT pattern and to predict the FEC symbol error performance
• +/-
105 ppm line frequency adjustment per electrical lane in BERT mode. Each electrical lane can be adjusted to a
different ppm value on
106Gb/s electrical lanes.
• Rx Eye Histogram analysis (Planned) Layer 1 support
400GE PAM4 speeds for 53Gb/s electrical lanes
PAM4
400/200/100/50GE speeds:
• KP4 (RS-544,514) Ethernet Forward Error Correction, Clause
119
• FEC symbol 误差 injection · 全部速度
• FEC Codeword symbol error correction distribution statistics
• PCS Rx per lane and port statistics
• Layer
1 BERT with PRBS-7Q, PRBS-9Q, PRBS-11Q, PRBS-13Q, PRBS-15Q, PRBS-20Q, PRBS-23Q, and PRBS-
31Q pattern support
• Layer
1 BERT with error injection
• BERT inferred FEC: The ability to run a BERT pattern and to predict the FEC symbol error performance
• +/-
105 ppm line frequency adjustment per electrical lane in BERT mode. Each electrical lane can be adjusted to a
different ppm value on
53Gb/s electrical lanes.
• Rx Eye Histogram analysis
条件:optics plus many other MSA compliant optical transceivers, AECs, ACCs, and AOCs.
OSFP800 optical transceiver support
Support for OSFP800 specification compliant optical transceivers up to 30 watts of consumption* (Power Class
8 and higher)
such as: 800ZR, 800GBASE-DR8, 800GBASE-2xFR4, 800GBASE-SR8, 400GBASE-DR4
400G-ZR and 400ZR+ coherent
Please consult the factory for additional transceiver support information from various manufacturers
See Optical Transceivers under the Ordering Information section of this data sheet for purchasable optical transceivers for this
OSFP800 Active Electrical Cable support Active Electrical Cable (AEC) and Active Copper Cable (ACC) support; please consult the factory for specific
OSFP800, passive copper cable support
OSFP800 passive copper cable support for up to 2.0 meters in length
OSFP800-to-QSFP800 conversion cable support for up to 2.0 meters in length
Auto-negotiation and Link Training support for passive copper direct attached cables (DAC) for all supported Ethernet speeds
Consult the factory for support of passive copper cable lengths that are longer than those stated above
Support for the CMIS 4.0 and 5.0 specifications including read/write access to all CMIS pages and registers
Support for C-CMIS
1.0 (Coherent CMIS)
Support for Application Selection Code (AppSel) feature of CMIS with auto-detection and transceiver configuration support
` 9
Product description Interconnect and Network Performance Tester 800GE OSFP800
2-port and 4-port chassis models
CMIS will operate with optical and copper interconnect media to the extent they are supported by the interconnect manufacturer
CMIS is exposed through the IxExplorer application and Tcl test automation support
Digital Optical Monitoring (DOM)
Automatically provides information from the interconnect device plugged into the test port, along with the device
status, electrical power, temperatures, power class, laser power and various LOL and LOS threshold and alarm
monitoring information. The DOM also provides feedback when alarms and thresholds are exceeded. This
capability is provided with the IxExplorer and IxNetwork applications.
800ZR
400G-ZR/ZR+ Coherent Optics
条件:connector and these operational conditions:
• The case temperature of the installed module is maintained at <= 70 degrees centigrade.
CMIS 5.0 and C-CMIS 1.0 (Coherent CMIS) provide Read/Write access to all management pages and Versatile Diagnostics
Monitoring (VDM) registers via IxExplorer GUI and Tcl test automation programming interface
Support for Application Selection Code (AppSel) feature of CMIS with auto-detection and configuration support
For optical transceivers that consume more than 20 watts of power, regardless of the form factor and technology type of the
optical transceiver, the Interconnect and Network Performance Tester
800GE chassis has been operated with optical
transceivers that consume up to 30 watts of power consumption. High power consumption transceivers such as
400ZR and
400ZR+ coherent optical transceivers have been fully qualified by Keysight in the Interconnect and Network Performance Tester
800GE chassis. 800ZR coherent optics that typically consume between
22 And 31 watts of power have been successfully
operated in the Interconnect and Network Performance Tester 800GE chassis subject to the full power limits of the host
• There are no alarms triggered on module itself
条件:• There are no over-temperature alarms triggered on the chassis itself.
The IxExplorer application supports the Digital Optical Monitoring (DOM) feature that automatically monitors and reports the
module case temperature, temperature warning limits, and the maximum temperature threshold limits. It is highly recommended
that the DOM feature be active to monitor the temperature behavior of installed high power consumption optical transceivers
before conducting long duration tests
Fixed chassis system dimensions 17.0” (L) ×10.86” (W) x
8.06” (H)
431.8 mm (L) x 275.7 mm (W) x
204.8 mm (H)
Fixed chassis system weights
条件:power source when running 100-120VAC, 10 Amps for the chassis power supply.
the 2-port or the 4-port benchtop chassis when 200-240 VAC is required.
Hardware only
22.0 lbs. (10.0 kg)
Estimated Shipping: 44 lbs. (20.0 kg)
1
1 Approximate (includes power cords, sync cables, and packaging)
Fixed chassis system electrical power 100-127VAC, 10A, 50/60 Hz 200-240 VAC, 4.5A
50/60Hz
One power cord is supplied with the unit. It is selected per the target country where the chassis is to be installed. Requires (1)
Requires (1) power source when running 200-240 VAC 4.5 Amps for the chassis power supply. For 200-240 VAC power cords
order part number 942-0110 from the Ordering Section of this datasheet. The kit is provided at no charge with the purchase of
Temperature (ambient air) Operating
41°F to 104°F (5 °C to 40°C)
Storage
-4°F to 122°F (-20 °C to 50°C)
Humidity (ambient air) Operating
5 % to 85 % RH, non-condensing
Storage
5 % to 85 % RH, non-condensing
UL 62368-1 / CSA C22.2 No.
62368-1
ICES-003(A)/NMB-003(A)
EN 55032 Class A, EN 55035, EN 61000-3-2, EN
61000-3-3
KS C 9832 Class A, KS C 9835, KS C 9610-3-2, KS C
9610-3-3
` 10
Product description Interconnect and Network Performance Tester 800GE OSFP800
2-port and 4-port chassis models
RoHS Directive 2011/65/EU, Directive (EU)
2015/863
Transmit engine Wire-speed packet generation with timestamps, sequence numbers, data integrity, and packet group signatures
Max. streams per port and 800GE PAM4
speeds 1x800GE: 64 (per FPP) 2x400GE: 64 (per fan-out) 4x200GE
64 (per fan-out)
(Planned) Max. streams per port and 400GE
PAM4 speeds
Sequential stream scheduler
Minimum frame size 800GE, 400GE
200GE and 100GE PAM4 speeds:
• 64 bytes at full line rate
• 61 bytes at less than full line rate (approximately
90% utilization)
(Planned) 400GE, 200GE
100GE and 50GE PAM4 speeds:
• 64 bytes at full line rate
• 60 bytes at less than full line rate
Maximum frame size for 800GE PAM4 speeds
16,000 bytes
(Planned) Maximum frame size for 400GE
Maximum frame size in data center Ethernet
9,216 bytes for all speeds
Priority flow control for 800GE PAM4 speeds
(Planned) for 400GE PAM4 speeds
8 line-rate-capable queues, each supporting up to 9216-byte frame lengths
Frame length controls Fixed, increment by user-defined step, weighted pairs (up to 16K in all speeds), uniform, repeatable random,
User-Defined Fields (UDF) Fixed, increment or decrement by user-defined step, sequence, value list, and random configurations; up to 8,
2x16 bit-wide UDFs are available.
Value lists (max.) per port for 800GE PAM4
speeds 1x800GE: 64K / port /UDF 2x400GE: 64K / port /UDF 4x200GE
32K /port /UDF
8x100GE
64K / 4-ports /UDF
(Planned) Value lists (max.) per port for 400GE
PAM4 speeds
` 11
Product description Interconnect and Network Performance Tester 800GE OSFP800
2-port and 4-port chassis models
Sequence (max.) for 800GE PAM4 speeds
(Planned) Sequence (max.) for 400GE PAM4
speeds 1x400GE: 32K / port /UDF 2x200GE: 32K / port /UDF 4x100GE
8K / port /UDF
L2/3 Ethernet in 800GE PAM4 mode only)
• FEC symbol error-injection allows the user to inject FEC symbol errors using various weighted methods to
achieve specific bit error rates (BER)
• Generate good CRC or force bad CRC, undersize and oversize standard Ethernet frame lengths, and bad
checksum (Planned) 误差发生 (FEC 和标配
Keysight L2/3 Ethernet in 400GE PAM4 mode
• FEC symbol error-injection allows the user to inject FEC symbol errors using various weighted methods to
achieve specific bit error rates (BER)
• Generate good CRC or force bad CRC, undersize and oversize standard Ethernet frame lengths, and bad
Physical coding sublayer for 800GE PAM4
speeds (Planned)
400GE PAM4 Ethernet speeds
Hardware checksum generation Checksum generation for IPv4, IP over IP, ICMP/GRE/TCP/UDP, L2TP, GTP, and multilayer checksum; support
Link fault signaling for all speeds
• Reports, no fault, remote fault, and local fault port statistics
• Generate local and remote faults with controls for the number of faults and order of faults
• Option to have the transmit port ignore link faults from a remote link partner and send traffic anyway
Latency measurement resolution for 800GE
PAM4 speeds
(Planned)
400GE PAM4 Ethernet speeds
Intrinsic latency compensation Removes inherent latency error from the port electronics for all speeds
Transmit line clock adjustment
• Ability to adjust the parts-per-million (ppm) line frequency: +/-
105 ppm on all the ports of the fixed
• Ability to adjust the clock ppm over a range of +/-
105 ppm in the BERT mode on a per lane basis
Receive engine Wire-speed packet filtering, capturing, real-time latency, and inter-arrival time for each packet group, with data
Trackable receive flows per port without
Sequence checking and with Tx/Rx synch for 800GE PAM4 Ethernet speeds 800GE, 400GE, 200GE: 32K full statistics 100GE
4K full statistics and 32K with minimum statistics
Trackable receive flows per port with and without Sequence checking and no Tx/RX synch for 800GE PAM4 Ethernet speeds 800GE, 400GE, 200GE
32K full statistics
100GE
8K full statistics and 32K with minimum statistics
(Planned) Trackable receive flows per port with and without Sequence Checking with Tx/Rx
Synch for 400GE PAM4 Ethernet speeds
400GE and 200GE
32K full statistics
100GE
4K full statistics and 32K with minimum statistics
(Planned) Trackable receive flows per port with and without Sequence Checking and no Tx/RX
Synch for 400GE PAM4 Ethernet speeds
400GE and 200GE
32K full statistics
100GE
4K full statistics and 32K with minimum statistics
Minimum frame size for all speeds • 60 Bytes at full line rate (requires the IxExplorer application)
• 56 Bytes at less than line rate Bytes (requires the IxExplorer application)
Filters (user-defined statistics, UDS) 2 SA/DA pattern matchers, 2x16-byte user-definable patterns.
6 UDS counters are available with offsets for start
` 12
Product description Interconnect and Network Performance Tester 800GE OSFP800
2-port and 4-port chassis models
Hardware capture buffer 1 MB available per front panel OSFP800 port and for the fan-out modes on that port
条件:Frame Loss Ratio, Pre-FEC Bit Error Rate, and Codeword error distribution analysis.
Link state, line speed, frames sent, valid frames received, bytes sent/received, fragments, undersize, oversize, CRC errors
6
user-defined stats, capture trigger (UDS 3), capture filter (UDS
4), data integrity frames, data integrity errors, sequence
checking frames, sequence checking errors, ARP, and PING requests and replies
FEC statistics for 800GE PAM4 Ethernet
speeds (Planned) for 400GE PAM4 Ethernet speeds
800GE PAM4 speeds:
FEC port statistics: Total Bit Errors, Max Symbol Errors, Corrected Codewords, Total Codewords, Uncorrectable Codewords,
FEC per lane Rx statistics: FEC Symbol Error Count, Corrected Bits Count, Symbol Error Rate, Corrected Bit Rate
Latency / jitter measurements Cut-through, store and forward, forwarding delay, latency/jitter, MEF jitter, and inter-arrival time
Receive-side PCS lanes port statistics counters for all speeds PCS: Sync Errors, Illegal Codes, Remote Faults, Local Faults, Illegal Ordered Set, Illegal Idle, and Illegal SOF
PCS receive-side statistics and indicators for 800GE PAM4 Ethernet speeds (Planned)
400GE PAM4 Ethernet speeds
Per-lane PCS receive capabilities include
Receive — per-lane PCS receive statistics, Physical Lane assignments, Lane Marker Lock, Lane Market Map, Relative Lane
Receive — per-lane FEC receive statistics; FEC Symbol Error Count, FEC Corrected Bits Count, FEC Symbol Error Rate, FEC
条件:SER statistics, comparison of signal quality between lanes and an array of eye measurements.
Advanced Rx Eye Histogram Analysis Advanced Rx Eye Histogram Analysis provides in-depth, user-selected, per lane PAM4 signal shape analysis,
Interconnect and Network Performance Tester
800GE benchtop chassis models
IxExplorer: Layer 1-3 wire-speed traffic generation, capture, and analysis with Layer
1 BERT, Forward Error Correction
analysis and error injection with statistics, PCS Lanes Tx/Rx with statistics and reporting capability. IxTcl API for custom
user script development for Layer
1–3 testing using the IxExplorer features
(Planned) IxNetwork: Wire-rate traffic generation with service modeling that builds realistic, dynamically controllable
data-plane traffic. IxNetwork offers the industry's best test solution for functional and performance testing by using
comprehensive emulation for routing, switching, MPLS, IP multicast, broadband, authentication, Carrier Ethernet, and
data center Ethernet protocols. Included with IxNetwork are test automation tools based on TCL, Python, and the
条件:Includes all 1x800GE, 2x400GE, 4x200GE, and 8x100GE Ethernet speeds (941-0093).
Includes all 1x800GE, 2x400GE, 4x200GE, and 8x100GE Ethernet speeds (941-0094).
Interconnect and Network Performance Tester
2-port hardware chassis and 4-port hardware chassis
941-0093
Interconnect and Network Performance Tester
2-port benchtop chassis with native OSFP800 front panel ports, L1-3 support
941-0094
Interconnect and Network Performance Tester
4-port benchtop chassis with native OSFP800 front panel ports, L1-3 support
930-3300
RoCEv2 Lossless Ethernet Enablement for Interconnect and Network Performance Tester (930-3300); Perpetual node-locked
license; Enable RoCEv2 capability for INPT-800-2P-OSFP-BT
2-port benchtop with OSFP800 ports (941-0093), INPT-800-4P-
OSFP-BT 4-port benchtop with OSFP800 ports (941-0094), and INPT-1600-2P-BT
2-port benchtop chassis with OSFP1600 ports
(941-0095), and INPT-1600-2P-RM
2-port half-rack chassis with OSFP1600 ports (941-0096); One option is required for each
` 13
Multiple Chassis synchronization
942-0090
Metronome Timing System and Metronome Timing Software enabling advanced chassis timing. Includes Sync Cable
5m (942-
0096). Compatible with the XGS-SD chassis, XGS-SDL chassis, XGS-HSL chassis, AresONE fixed chassis, Novus ONE PLUS
fixed chassis and Interconnect and Network Performance Tester
800GE.
OSFP800
800GE optical transceivers
Keysight, OSFP800-DR8-XCVR, 800GBASE-DR8, Single Mode Fiber, 500-meter reach with FEC
1310nm center wavelength
100G Lambda, optical transceiver (948-0071). CMIS
4.0 compliant. Compatible with Ixia cables: OSFP800-DR8-CBL MPO16 APC-
APC, SMF, 3-meter and OSFP800-DR8-FO-CBL, fan-out, MPO16, APC-UPC, SMF, MPO16-to-8x100GE LC
3-meter. This
transceiver is compatible with all AresONE
800GE OSFP800-C and OSFP800-M fixed chassis models, and with the G800GE-02
800GE OSFP800 and OSFP800-COAX chassis models.
条件:Dual Interface Model-M fixed chassis models. It supports 2x400GE PAM4 signaling output.
Keysight, OSFP800-2XFR4-XCVR 2x400GE pluggable optical transceiver, SMF (single mode)
4 lambdas per port, Dual duplex LC
connector, 2km reach (948-0091). This optical transceiver is compatible with AresONE 800GE-M OSFP800 and AresONE
800GE
OSFP800
800GE fiber point-to-point cable
OSFP800-DR8-CBL Keysight, OSFP800-DR8-CBL, point-to-point, MPO16, APC-APC, Single Mode Fiber (SMF) cable
2-m
以上指标摘自厂家官方数据手册,完整定义、测试条件与保证值口径以手册为准。完整指标、测试条件与定义口径请见产品页「软件和手册 | 白皮书」栏目中的官方数据手册。
是德科技 | KEYSIGHT · onetest 仪器资源库