是德科技 | KEYSIGHT
N6950A 电源 1000W 详细指标
ATE System Power Supplies
一、List of APS power supplies(表 1)
Series 1 kW models
2 kW models
Keysight N6900 Series DC power supplies • N6950A 9 V
100 A
Keysight N7900 Series dynamic DC power supplies • N7950A 9 V
100 A
Test challenges and how the APS helps you overcome them
The APS, with Keysight’s exclusive VersaPower architecture, helps you overcome a wide variety of power
二、Test challenges and how the APS helps you overcome them(表 2)
Power-related test challenge How the APS helps you overcome the challenge
Increasing test system throughput
条件:Reducing test time can mean big savings, so achieving throughput gains is a never-ending quest.
• Fast up and down programming speeds (up to 500 μs)
• Fast command processing (<
2 ms)
• List capability to step through a list of voltage or current levels
• Seamless ranging capability for fast current measurements without sacrificing accuracy
• Full two-quadrant glitch-free operation across quadrants
• Voltage and current limit settings to keep your device within its
Characterizing dynamic current profiles
Your DUT has a current profile with a large dynamic range that
• 18-bit high-resolution current digitizer
• Pre- and post-triggering for capturing measurement data
• Large current range that is over
2x the rated output of the
条件:Maintaining output integrity under dynamic load conditions
Maintaining a stable output voltage free of oscillations and voltage droop can be a challenge under a very dynamic load, especially when working with long cable runs.
• Fast transient response to ensure minimal voltage droop to load transients
• High and low output bandwidth settings for tuning the output
• Built-in Black Box Recorder
• Records voltage, current, power, trigger events, mode changes, and more in non-volatile memory
Properly powering on/off a DUT
To prevent damage at turn-on or turn-off, you need to properly
• Sequencing capability across multiple APS supplies
• Sequencing capability with Keysight’s N6700 modular power
Overcome Your Power Test Challenges
Accelerate test throughput with industry-leading specifications
Shaving seconds or even milliseconds off a test time can lead to significant savings for high- volume
manufacturers, making throughput gains a never-ending quest for test system designers. The APS is a
valuable tool for increasing throughput. It provides a number of industry-leading specifications and
innovative features that can help you achieve significant throughput gains in your testing. Some
• Industry-leading command processing time (<2 ms)
• Fast up and down programming speeds (up to 500 μs)
• Adjustable measurement times for optimum measurements in minimum time
• Seamless ranging capability for fast current measurements without sacrificing accuracy
• Output lists that allow you to step through timed or triggered voltage or current levels that can also
generate triggers for tightly synchronized measurement
Figure
1. Dynamic current measurement
Accurately characterize your DUT’s power profile with advanced
The APS provides simultaneous voltage and current measurement capabilities that deliver high accuracy
and resolution. Make measurements using two main modes: averaged or digitized. In average mode, the
APS delivers high-accuracy DMM-quality voltage and current measurements. The digitizing capability
allows you to capture dynamic current or voltage profiles at a much higher resolution than an
• Capture inrush current: APS provides an
18-bit current digitizer with a sample rate of up to 200 kS/s
level triggers, and a current measurement range that is
2.25x as high as the max output current
条件:hour calculations. These measurements help simplify your power efficiency and storage calculations.
• Accurately capture dynamic current profiles: APS has two current measurement ranges that allow it
to measure micro-amps to amps. The APS uses seamless ranging technology to transition from one
measurement range to the other without discontinuities in the output power or in measurement data
• Accurately measure power storage and efficiency: In addition to high-accuracy voltage and current
measurement capabilities, APS power supplies offer built-in power, peak power, amp-hour, and watt-
条件:current without changing the power supply’s output characteristics or introducing any disruptive behavior.
storage applications. For more information on the APS N7909A, see page 12 .
• Adjustable measurement intervals for both average and digitized measurements
• External logging capability, which simplifies data logging in ATE software
• Pre-, post-, and level-triggering for pinpointing exactly where and when to measure
Reduce ATE development time and support costs with integrated features
Continuously source and sink current for power storage test applications
When operated as standalone units, APS power supplies can continuously sink up to 10% of their rated
output current for an indefinite time. With the addition of APS N7909A power dissipater units, APS power
supplies can continuously sink up to 100% of their rated output current. This means you can sink the
power supply’s full-rated output power for an indefinite time. Note that the two-quadrant sourcing and
sinking capability of the DC power supply allows for continuous transitions between sourcing and sinking
These capabilities make the APS an ideal solution for continuous source and sink testing needs in power
Figure
2. When you add N7909A power dissipater units
to an APS supply, you extend its ability to sink current from 10% to 100% of its rated current
Figure
3. Shows an example of an APS power supply
smoothly pulsing back and forth from sinking current at
条件:voltage level captured at high resolution on the top trace remains constant with no glitches.
-10 A to sourcing current at 10 A. Notice that the
To complement the two-quadrant operation, all APS power supplies have built-in programmable output
resistance capability. This capability allows an APS power supply to simulate the internal resistance of
Smart triggering: Increase throughput, protect your DUT, and reduce
条件:you would expect in a system power supply, but it goes well beyond with capabilities such as:
• Level triggering allows you to execute a trigger from five different APS measurement parameters:
The APS’s smart triggering system provides trigger capabilities never before seen in a power supply. The
APS’s smart triggering can accelerate your test throughput, better protect your DUT, and reduce the
complexity of your test system. The smart triggering system includes all the basic triggering functionality
电压, 电流, 功率, amp-hour, 和 watt-hour
条件:various trigger conditions such as digital input pins, level triggers, status bits, and more.
• Logical triggering gives you the ability to create logical “and,” “or,” and “not” trigger expressions using
• Triggers can be used to transition through a list of voltage or current levels as well as through the
• Triggers with precision delays can be sent out from the APS after a voltage or current level
change/transient. These triggers can be used to signal another instrument in the test system to do
Track power events with a black box recorder
条件:supply. Much like an airplane flight data recorder, the APS black box recorder is always recording events.
non-volatile memory regardless of what the power supply is doing or how it is being used.
If you are testing expensive prototypes and a power-related problem damages or destroys your DUT, you
need to figure out what went wrong to ensure it does not happen again. The APS’s optional black box
recorder (BBR option) overcomes this test challenge by creating a power event record inside the power
When the power supply is on, it is always running, recording power events, and making measurements in
Examples of what it records
• Voltage (min, max, and avg), current (min, max, and avg), and power (min, max, and avg)
See page
13 for more information on the APS BBR Option.
Avoid damage to your DUT with APS protection
条件:When you are testing costly DUTs, integrating power protection measures into the test system is critical.
Using instrumentation with built-in protection features provides a huge benefit when DUT protection is
条件:hardware needed in the test system, reducing complexity and development time.
test system is reduced, which in turn lowers test system support costs.
conditions can be detected and handled much faster, reducing the likelihood of the DUT sustaining
• Built-in protection features, such as broken sense line detection, reduce the amount of protection
• With protection features integrated into the instrumentation, the amount of hardware needed for the
• With protection measures implemented in hardware rather than test system software, error
The APS power supplies feature advanced and fast protection capabilities fully integrated
These protection capabilities include
• Fast CC/CV mode crossover as well as user-settable voltage and current priority modes to reduce
Generate voltage and current transients
条件:DUT can stand up to these real-world transients, you must simulate worst-case power transient conditions
DUTs that are operated in rugged environments, such as automotive electronics and avionics, can often
experience transient behavior from the power source, such as voltage dropouts or surges. To ensure your
in the test process. The APS power supplies provide three different functionalities for simulating either
电压或电流 transients · testing
条件:A one-time event that steps the output voltage or current up or down in response to a triggered event.
Arbitrary waveforms: An arbitrary waveform generator (arb) allows you to generate complex user-
defined voltage or current waveforms of up to 65,535 data points.
List: A list can consist of up to 512 steps. Each step in the list can have a unique dwell time associated
with it, which specifies the time in seconds that the list will remain at that step before moving on to the
next step. Lists can also be trigger-paced, in which case the list advances one step for each trigger
条件:current transients, refer to the specifications section in this document or the APS user manual.
For a demonstration of the APS’s arb capability, an example “interrupt” pulse was generated with the
N7951A into a resistive load. The interrupt pulse goes from 20 V to 2 V for 10 ms and then returns to 20
V. The resulting interrupt pulse was captured (Figure 4), and its fall time was measured to be <
200 μs
(Figure
5). For more information on the APS’s output bandwidth and speed for generating voltage and
Figure 4. Voltage interrupt pulse generated by N7951A Figure
5. Interrupt pulse fall time measurement of <
200 us
Properly powering on and off your DUT with the APS
条件:and latch-up conditions. In addition to sequencing on or off each supply, you may need to set the ramp
If you work with DUTs that have multiple power supply inputs, such as satellite payloads, you often need
to properly sequence on or off each power supply at strictly repeatable times to prevent current surges
rate of each supply at turn-on or turn-off to a particular rate. These requirements add significant
complexity to an ATE test system, both in hardware and software.
The APS power supplies can help you overcome this test challenge by providing built -in sequencing
capability across APS mainframes or with Keysight’s popular N6700 family of modular system power
supplies. Also, the APS power supplies provide adjustable slew rate control at turn- on or turn-off. These
built-in capabilities provide a clean, low-complexity way to properly power on or off your DUT during the
条件:Paralleling multiple power supplies together is a great way to add power flexibility to your test system.
and the other supply will source only a fraction of the current and operate in CV mode. This condition can
highly degrade certain power supply performance specifications, such as transient response.
Add power flexibility to your test system by paralleling multiple APS supplies
The downside of paralleling power supplies together is you cannot get all the supplies to operate in the
desired constant voltage (CV) or constant current (CC) mode. For instance, when trying to operate in CV
mode with two parallel supplies, one will typically source the bulk of the current and operate in CC mode,
With the APS you do not have to worry about this since it has built-in paralleling capability that ensures
each supply equally shares the load current so they all remain in the desired mode, whether it is CV or
CC. Note that paralleling works whether the APS power supplies are sourcing or sinking current from
条件:five APS power supplies (recommended), which provides a maximum power of 10 kW.
To take advantage of the APS paralleling capability, you need only a simple three- wire connection in the
rear of the supplies in the parallel configuration (see Figure
6). With this capability, you can parallel up to
Figure
6. An APS supply’s three-wire connection for paralleling multiple supplies
On how the APS can help you overcome your power-related test challenges, including
条件:supply, so you will need two N7909As to achieve the full two-quadrant operation of a 2 kW APS supply.
You can use a single N7909A with a 2 kW APS power supply to achieve 50% current sinking capability.
wire power connection and a communication connection to provide continuous two -quadrant operation.
The connections are located on the rear panel of both the N7909A and the supply, as shown in Figure 7.
The N7909A does not operate as a standalone instrument. It only works with an APS power supply.
APS N7909A power dissipater unit
The optional N7909A power dissipater unit adds current sinking or two-quadrant operation to any N6900
or N7900 power supply. Each N7909A provides up to 1 kW of current sinking capability to an APS power
The N7909A form factor is
1U with full rack width. N7909A connects to an APS power supply via a two-
Figure 7. N7909A power dissipater unit rear connections to a
1 kW APS power supply
Additional information on the APS’s
2-quadrant operation:
• The APS provides programmable ± current waveform capability to fully utilize the two- quadrant
• The APS provides ± current limit settings to ensure your device is operated in its allowable range
• By default, the APS’s current sink capability will perform down programming for pulling down voltage
levels when it is connected to loads with stored energy, for instance, loads with a large amount of
条件:output current sinking capability without the N7909A power dissipater unit.
2. Note: Even though the APS’s two- quadrant operation gives it much of the same functionality as a DC electronic load, it cannot
• All these capabilities are also available when you use a standalone APS power supply’s
10% rated
simulate current transients as fast as an electronic load. For instance, the APS can simulate full range - /+ current transients at
~ 5 ms, where a high- performance electronic load can achieve current transients <
1 ms. See the specifications and user guide
APS black box recorder (option BBR)
Much like a flight data recorder, the black box recorder (BBR) runs continually in the background,
independent of what the power supply is doing. When the power supply is on, the BBR is recording power
events and storing measurements in non-volatile memory. The BBR can be set for either a
24-hour
record or a 10-day record period. In the
24-hour mode, measurements are made at a rate of 100 per
second, and in the
10-day mode, they are made at a rate of 10 per second. The BBR data can be
accessed via the free APS power assistant software (see Figure 8 on page
13 ). The BBR option works on
all APS N6900 and N7900 power supplies. It is a factory-installed option available only at the time of
条件:is needed for every APS power supply or N7909A dissipater that you would like to mount.
The APS N7906A power assistant software is a free application that works with the APS power supplies.
The power assistant software provides three main capabilities for working with the APS power supplies:
APS N7910A rack mount kit
The N7910A rack mount kit can be used for all N6900 and N7900 power supplies, regardless of if they
are
1 kW or 2 kW form factors. It can also be used for mounting the N7909A. N7910A APS rack mount kit
The N7910A is intended for use in a 19-inch EIA rack cabinet. APS power supplies and power dissipater
units can be mounted directly above or below each other without any worry of heat problems. For
installation instructions and other rack-mounting options, refer to the APS user manual at
N7906A power assistant software
• Control an APS power supply using the Power Assistant software’s intuitive graphical user interface
• Retrieve and view data from the optional APS power supply black box recorder (see Figure
8)
• Perform trigger routing and configure logical trigger expressions (see Figure
9)
more information on the APS power assistant software, refer to the APS user manual at
Figure
8. Black box recorder data displayed within the
N7906A Power Assistant software
Figure
9. Configuring a trigger expression with the
N7906A Power Assistant software
Differences Between the APS N6900 Series and N7900
三、This table compares 性能规格和特性 N6900 DC Series(表 3)
power supplies and the N7900 Series dynamic DC power supplies.
models N7900
1 kW and 2 kW models
Voltage and current programming
14-bit precision
16-bit precision
Voltage and current measurements 18-bit precision
18-bit precision
Voltage up / down programming time1
3 ms / 3 ms
0.5 ms / 0.35 ms with
0.5 ms / .35 ms
Transient response time (recovery time)1 100 us
100 us
Two-quadrant operation (10% standard
100% optional) Yes Yes
Parallel operation Yes Yes · APS Specifications
N6900 specifications
1 kW / 2 kW
四、N6900 规格 1 kW / 2 kW(表 4)
N6950A / 70A N6951A / 71A N6952A / 72A N6953A / 73A N6954A / 74A N6976A N6977A
Current sink @10%
Current sink @100%1
Power 0 to 9 V
100 A / 200 A
-10 A / -20 A
-100 A / -200 A
900 W / 1.8 kW
0 to 20 V
50 A / 100 A
-5 A / -10 A
-50 A / -100 A
1 kW / 2 kW
0 to 40 V
25 A / 50 A
-2.5 A / -5 A
-25 A / -50 A
1 kW / 2 kW
0 to 60 V
16.7 A / 33.3 A
-1.67 A / -3.33A
-16.7 A / -33.3 A
1 kW / 2 kW
0 to 80 V
12.5 A / 25 A
-1.25 A / -2.5 A
-12.5 A / -25 A
1 kW / 2 kW
0 to 120 V
16.7 A
-1.67 A
-16.7 A
2 kW
0 to 160 V
12.5 A
-1.25 A
-12.5 A
2 kW
Output ripple & noise2
CV peak-to-peak 1 mV 9 mV
1 mV
9 mV
1 mV
9 mV
1 mV
9 mV
1 mV
9 mV
2 mV
30 mV
3 mV
30 mV
条件:Curr programming and measurement accuracy3 with Option 0.1% +30 / 60 mA
Curr. Measurement ranges5 (with Option 301)
Current 0.5 mV 8 mA / 15 mA
0.75 mV
3 mA / 6 mA
1.5 mV
1 mA / 2 mA
2 mV
1 mA / 1.5 mA
2 mV
0.8 mA / 1.5 mA
4 mV
1 mA
4 mV
0.8 mA
Volt programming & meas. accuracy3
0.04%+15/30mA
0.04%+2.5/5mA
High range N695x
High range N697x
Low range N695x
Low range N697x
-225 A to 225 A
-450 A to 450 A
-11 A to 11 A
-22 A to 22 A
-112.5Ato112.5A
-225 A to 225 A
-5.5 A to 5.5 A
-11 A to 11 A
-56.2 A to 56.2 A
-112.5 A to 112.5A
-2.75 A to 2.75 A
-5.5 A to 5.5 A
-37.6 A to 37.6 A
-74.9 A to -74.9 A
-1.84 A to 1.84 A
-3.67 A to 3.67 A
-28.1 A to 28.1 A
-56.2 A to 56.2 A
-1.37 A to 1.37 A
-2.75 A to 2.75 A
-37.6 A to 37.6 A
-1.84 A to 1.84 A
-28.1 A to 28.1 A
-1.37 A to 1.37 A
Transient response4
Settling band 100 us 150 mV
100 us
150 mV
100 us
100 mV
100 us
150 mV
100 us
200 mV
100 us
300 mV
100 us
400 mV
Volt up & down programming time6
10% to 90% and 90% to 10% Settling time
3 ms
10 ms
3 ms
10 ms
3 ms
10 ms
3 ms
10 ms
3 ms
10 ms
3 ms
10 ms
3 ms
10 ms
O,5 ms
1 ms
O,5 ms
1 ms
O,5 ms
1 ms
O,5 ms
1 ms
O,5 ms
1 ms
O,5 ms
1 ms
O,5 ms
1 ms
Resistance programming6
Resolution 0 to 0.1 / 0.05 Ω 0.12% +1.6 mΩ*A
0.8 μΩ / 0.4 μΩ
0 to 0.4 / 0.2 Ω
3.4 μΩ / 1.7 μΩ
0 to 1.6 / 0.8 Ω
13 μΩ / 7 μΩ
0 to 3.4 / 1.7 Ω
30 μΩ / 15 μΩ
0 to 6.4 / 3.2 Ω
54 μΩ / 27 μΩ
0 to 6.8 Ω
60 μΩ
0 to 12.8 Ω
108 μΩ
N7900 specifications
1 kW / 2 kW
五、N7900 规格 1 kW / 2 kW(表 5)
N7950A / 70A N7951A / 71A N7952A / 72A N7953A / 73A N7954A / 74A N7976A N7977A
Current sink @10%
Current sink @100%1
Power 0 to 9 V
100 A / 200 A
-10 A / -20 A
-100 A / -200 A
900 W / 1.8 kW
0 to 20 V
50 A / 100 A
-5 A / -10 A
-50 A / -100 A
1 kW / 2 kW
0 to 40 V
25 A / 50 A
-2.5 A / -5 A
-25 A / -50 A
1 kW / 2 kW
0 to 60 V
16.7 A / 33.3 A
-1.67 A / -3.33 A
-16.7 A / -33.3 A
1 kW / 2 kW
0 to 80 V
12.5 A / 25 A
-1.25 A / -2.5 A
-12.5 A / -25 A
1 kW / 2 kW
0 to 120 V
16.7 A
-1.67 A
-16.7 A
2 kW
0 to 160 V
12.5 A
-1.25 A
-12.5 A
2 kW
Output ripple & noise2
CV peak-to-peak 1 mV 9 mV
1 mV
9 mV
1 mV
9 mV
1 mV
9 mV
1 mV
9 mV
2 mV
30 mV
3 mV
30 mV
Current 0.5 mV 8 mA / 15 mA
0.75 mV
3 mA / 6 mA
1.5 mV
1 mA / 2 mA
2 mV
1 mA / 1.5 mA
2 mV
0.8 mA / 1.5 mA
4 mV
1 mA
w4 mV
0.8 mA
Volt programming and measurement accuracy3
V rating 0.03% +1 mV 0.03% +1.4 mV 0.03%
+2 mV
Curr. programming and measurement accuracy3 0.04% +15 / 30 mA 0.04% +8 / 15 mA 0.04% +4 / 8 mA 0.04% +2.5 / 5 mA 0.04% +2 / 4 mA 0.04% +2.5 mA 0.04%
+2 mA
Current measurement low-range accuracy3 0.05% +3/6 mA 0.05% +1/2 mA 0.05% +0.6/1.2 mA 0.05% +0.3/0.6 mA 0.05% +0.25/0.5 mA 0.05% +0.4 mA 0.05%
+0.25 mA
Curr. Measurement ranges5
High range N795x
High range N797x
Low range N795x
Low range N797x
-225 A to 225 A
-450 A to 450 A
-11 A to 11 A
-22 A to 22 A
-112.5 A to 112.5A
-225 A to 225 A
-5.5 A to 5.5 A
-11 A to 11 A
-56.2 A to 56.2 A
-112.5 A to 112.5A
-2.75 A to 2.75 A
-5.5 A to 5.5 A
-37.6 A to 37.6 A
-74.9 A to -74.9 A
-1.84 A to 1.84 A
-3.67 A to 3.67 A
-28.1 A to 28.1 A
-56.2 A to 56.2 A
-1.37 A to 1.37 A
-2.75 A to 2.75 A
-37.6 A to 37.6 A
-1.84 A to 1.84 A
-28.1 A to 28.1 A
-1.37 A to 1.37 A
Transient response4
Settling and 100 μs 150 mV
100 μs
150 mV
100 μs
100 mV
100 μs
150 mV
100 μs
200 mV
100 μs
300 mV
100 μs
400 mV
Volt up programming time6
10% to 90%
Settling time 0.5 ms 1 ms
0.5 ms
1 ms
0.5 ms
1 ms
0.5 ms
1 ms
0.5 ms
1 ms
0.5 ms
1 ms
0.5 ms
1 ms
Volt down programming time6
90% to 10%
Settling time 0.35 ms 0.8 ms
0.35 ms
0.8 ms
0.35 ms
0.8 ms
0.35 ms
0.8 ms
0.35 ms
0.8 ms
0.35 ms
0.8 ms
0.35 ms
0.8 ms
Voltage programming bandwidth (no load)6
-3 dB point
-1 dB point
2 kHz
1 kHz
2 kHz
1 kHz
2 kHz
1 kHz
2 kHz
1 kHz
2 kHz
1 kHz
2 kHz
1 kHz
2 kHz
1 kHz
Curr. up-programming time610% to 90% 2.5 ms 2.5 ms 2.5 ms 2.5 ms 2.5 ms 2.5 ms
2.5 ms
Current programming bandwidth (resistive load)6
-3 dB point
-1 dB point
160 Hz
70 Hz
160 Hz
70 Hz
160 Hz
70 Hz
160 Hz
70 Hz
160 Hz
70 Hz
160 Hz
70 Hz
160 Hz
70 Hz
Resistance programming6
条件:1. Current sinking up to 100% of rated current requires one N7909A power dissipater for 1 kW models and two N7909A power
dissipaters for 2 kW models. 2 kW models with one power dissipater can sink 50% of their rated current.
2. From 20 Hz to 20 MHz
3. Expressed as % of setting (or % of measurement) + offset. At 23 °C ±5 °C after a 30 -minute warm -up , measurement.
4. Time to recover within the settling band following a load change from 50% to 100% of full load.
5. When sinking current, the negative current measurement ranges match the positive current measurement ranges.
6. These are supplemental characteristics .
Resolution 0 to 0.1 / 0.05 Ω 0.06% +1.6 mΩ*A
0.8 μΩ / 0.4 μΩ
0 to 0.4 / 0.2 Ω
3.4 μΩ / 1.7 μΩ
0 to 1.6 / 0.8 Ω
13 μΩ / 7 μΩ
0 to 3.4 / 1.7 Ω
30 μΩ / 15 μΩ
0 to 6.4 / 3.2 Ω
54 μΩ / 27 μΩ
0 to 6.8 Ω
60 μΩ
0 to 12.8 Ω
108 μΩ
NPLC=1; valid for 1 year.
六、Two-quadrant specifications(表 6)
+ Voltage rating 9 V 20 V 40 V 60 V 80 V 120 V
160 V
+Current rating 100 A/200 A 50 A/100 A 25 A/50 A 16.7 A/33.3 A 12.5 A/25 A 16.7 A
12.5 A
-Curr rating (w/dissipater) -100 A/-200 A -50 A/-100 A -25 A/-50 A -16.7 A/-33.3 A -12.5 A/-25 A -16.7 A
-12.5 A
V1 0.68 V 0.525 V 1.9 V 1.47 V 2.0 V 3 V
4 V
V2 0.068 V 0.0525 V .19 V .147 V 0.2 V 0.3 V
0.4 V
APS N6900 Series and N7900 Series power supply power
条件:nominal line voltages in the range of 100 VAC to 240 VAC. The frequency can be 50 Hz, 60 Hz, or 400
its maximum output power will be limited to 700 W. In this condition, if the power supply exceeds 700 W
of output power, the instrument turns off the output and sets the CP+ status bit.
Connect the power cord that was supplied with your unit to the AC mains connector on the rear of the
unit. Note that these cords are standard and are specially rated to handle the power needs of the APS
supply they are shipped with. The AC input on the back of your unit is a universal AC input. It accepts
Hz. AC mains rated below 180 VAC cannot supply enough current to power either the 1 kW or the
2 kW
N6900 and N7900 models to their full-rated output power. In such cases, when a
1 kW or 2 kW APS
power supply is connected to below 180 VAC AC mains, the power supply will still operate normally, but
APS power supply connectivity
All APS power supplies come standard with GPIB (IEEE-488), LAN (LXI-Core), and USB remote
programming interfaces. GPIB and LAN parameters can be set via the front panel. The APS is LXI Core
2011 compliant and includes a built-in Web interface. This means you can control the APS remotely using
条件:Weight and dimensions are the same for the N6900 Series and N7900 Series APS power supplies:
• 1 kW power supplies
• Weight
24 lbs. (10.9 kg.)
• Dimensions: L 22.39 in / 568.7 mm, W 16.81 in / 426.9 mm, H
1.75 in / 44.45 mm
• 2 kW power supplies
• Weight
34 lbs. (15.5 kg.)
• Dimensions: L 24.928 in / 633.2 mm, W 16.81 in / 426.9 mm, H
3.468 in / 88.1 mm
• Weight
18 lbs. (8.2 kg.)
• Dimensions: L 19.81 in / 503.3 mm, W 16.81 in / 426.9 mm, H
1.75 in / 44.45 mm
条件:describes the possible pin configuration for the digital port functions.
On the rear panel of every APS power supply is a digital control port that consists of seven I/O pins that
provide access to various control functions, as shown in Figure 10. Each pin is user -configurable. Table
7
For more information on the digital control port and how to configure it, refer to the Advanced Power
Figure
10. Digital control port on the rear panel
以上指标摘自厂家官方数据手册,完整定义、测试条件与保证值口径以手册为准。完整指标、测试条件与定义口径请见产品页「软件和手册 | 白皮书」栏目中的官方数据手册。
是德科技 | KEYSIGHT · onetest 仪器资源库