扫描速率:65 周期/秒
模式(n线):1线
总线连接器:PXI混合
最大直流切换电流:12 A
10通道、12 A、1-Wire PXI多路复用器开关模块
ONETEST 欢迎您
厂商登录 | 入驻
登录 | 注册 购物车 微信公众号厂商登录
扫描速率:65 周期/秒
模式(n线):1线
总线连接器:PXI混合
最大直流切换电流:12 A
10通道、12 A、1-Wire PXI多路复用器开关模块
以下指标取自 Teledyne 官方在线规格书,按原文档小节分组。
| CHx | Signal connection |
| COM0 | Routing destination for all channels |
| Maximum switching voltage Channel-to-channel 300 V Channel-to-ground 300 V, Measurement Category II | Channel-to-channel |
| Channel-to-channel | 300 V |
| Channel-to-ground | 300 V, Measurement Category II |
| Maximum switching power (per channel) AC systems 3 kVA (up to 60 Hz) | AC systems |
| AC systems | 3 kVA (up to 60 Hz) |
| Maximum current (switching or carry, per channel or common) Ambient temperature ≤45 °C 12 A | Ambient temperature ≤45 °C |
| Ambient temperature ≤45 °C | 12 A |
| DC path resistance Initial ≤50 mΩ End-of-life >100 mΩ | Initial |
| Initial | ≤50 mΩ |
| End-of-life | >100 mΩ |
| Minimum switch load | 12 V 100 mA |
| Bandwidth (-3 dB, 50 Ω termination) | ≥10 MHz, typical |
| Crosstalk (50 Ω termination) Channel-to-channel 10 kHz ≤-85 dB, typical 100 kHz ≤-65 dB, typical 1 MHz ≤-45 dB, typical 10 MHz ≤-25 dB, typical | Channel-to-channel 10 kHz ≤-85 dB, typical 100 kHz ≤-65 dB, typical 1 MHz ≤-45 dB, typical 10 MHz ≤-25 dB, typical |
| Channel-to-channel 10 kHz ≤-85 dB, typical 100 kHz ≤-65 dB, typical 1 MHz ≤-45 dB, typical 10 MHz ≤-25 dB, typical | 10 kHz |
| 10 kHz | ≤-85 dB, typical |
| 100 kHz | ≤-65 dB, typical |
| 1 MHz | ≤-45 dB, typical |
| 10 MHz | ≤-25 dB, typical |
| Isolation (50 Ω termination) Open channel 10 kHz ≥85 dB, typical 100 kHz ≥65 dB, typical 1 MHz ≥45 dB, typical 10 MHz ≥25 dB, typical | Open channel 10 kHz ≥85 dB, typical 100 kHz ≥65 dB, typical 1 MHz ≥45 dB, typical 10 MHz ≥25 dB, typical |
| Open channel 10 kHz ≥85 dB, typical 100 kHz ≥65 dB, typical 1 MHz ≥45 dB, typical 10 MHz ≥25 dB, typical | 10 kHz |
| 10 kHz | ≥85 dB, typical |
| 100 kHz | ≥65 dB, typical |
| 1 MHz | ≥45 dB, typical |
| 10 MHz | ≥25 dB, typical |
| Input trigger Sources PXI trigger lines <0...7> Minimum pulse width[1] 150 ns | Sources |
| Sources | PXI trigger lines <0...7> |
| Minimum pulse width[1] | 150 ns |
| Output trigger Destinations PXI trigger lines <0...7> Default pulse width 2 µs, typical | Destinations |
| Destinations | PXI trigger lines <0...7> |
| Default pulse width | 2 µs, typical |
| Relay operate time[2] | 15.4 ms, maximum |
| Expected relay life[3] Mechanical 1 × 107 cycles Electrical 30 V DC, 10 A DC resistive 1 × 105 cycles 30 V DC, 12 A DC resistive 3 × 104 cycles | Mechanical |
| Mechanical | 1 × 107 cycles |
| Electrical 30 V DC, 10 A DC resistive 1 × 105 cycles 30 V DC, 12 A DC resistive 3 × 104 cycles | 30 V DC, 10 A DC resistive |
| 30 V DC, 10 A DC resistive | 1 × 105 cycles |
| 30 V DC, 12 A DC resistive | 3 × 104 cycles |
| Relay type | Electromechanical, single-side stable |
| Relay contact material | Silver-nickel |
| I/O connector | 20-position, Positronic GMCT series plug |
| PXI power requirement | 5 W at 5 V 2.5 W at 3.3 V |
| Dimensions (L × W × H) | 3U, one slot, PXI/cPCI module, 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.) |
| Weight | 400 g (14 oz) |
| Maximum altitude | 2,000 m (at 25 °C ambient temperature) |
| Pollution degree | 2 |
| Ambient temperature range | 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) |
| Relative humidity range | 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
| Ambient temperature range | -20 °C to 70 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) |
| Relative humidity range | 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
| Operational shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) |
| Random vibration Operating 5 Hz to 500 Hz, 0.31 grms (Tested in accordance with IEC 60068-2-64.) Nonoperating 5 Hz to 500 Hz, 2.46 grms (Tested in accordance with IEC 60068-2-64. Test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) | Operating |
| Operating | 5 Hz to 500 Hz, 0.31 grms (Tested in accordance with IEC 60068-2-64.) |
| Nonoperating | 5 Hz to 500 Hz, 2.46 grms (Tested in accordance with IEC 60068-2-64. Test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) |
官方规格书:https://www.ni.com/docs/en-US/bundle/pxi-2585-specs/page/specs.html
NI官方渠道
官方渠道(官网 / 热线 / 邮箱)
官方渠道(中国大陆)
• 官网 www.ni.com/zh-cn
• 在线选购 www.ni.com/zh-cn/shop.html
• 经销商查询
官网「查找经销商」 www.ni.com/zh-cn/shop/advisors.html
• 联系方式
NI 中文官网不公布中国区电话与邮箱,报价、技术支持、校准、维修一律通过官网在线表单提交(「联系我们」页)
全国办事处
公司总部
• NI(National Instruments)
• 地址
11500 N Mopac Expwy, Austin, TX 78759-3504, United States
• 母公司
Emerson(2023 年完成收购,NI 隶属艾默生测试与测量业务集团)
0条提问
X
提问
X
回答
发表口碑
AI问答