At Fluke, we know accidents happen—tools will be dropped, kicked, stepped on or knocked over. You shouldn’t have to replace a tool because it fell off the workbench or was splashed with water or dirt. That’s why we designed the Ti。
Whether you are up on the roof inspecting heating, ventilation and air conditioning, deep in the plant scanning a motor, or if you are locking out an electrical panel, you rely on your tools to have the power and features to get y。
The Ti95 Fluke Connect FCC Kit is a great solution for quick and efficient inspections. This kit features the only wireless industrial infrared camera in its price class¹, the Ti95, and an a3001 FC iFlex module. Save time and incr。
  • «
  • 1

Ti480 PRO 640 x 480手持红外热像仪|福禄克 (在产)

Capturing and displaying temperature variances makes all the difference when diagnosing problems. The Fluke Ti480 PRO Infrared Camera has increased thermal sensitivity to capture minute differences and the latest Fluke technology 。

参考价格 :
产品描述
详细指标
软件和手册|白皮书
购买渠道
选件
问大家
视频
测评
口碑
系统与解决方案

Fluke Corporation · 红外热像仪

Ti480 PRO 手持红外热像仪

0.93 mRad, D:S 1065:1 · 640 x 480 · 307, 200 pixels · Yes · Yes · 2x and 4x
0.93 mRad, D:S 1065:1
IFOV with standard lens (spatial resolution)
640 x 480
Detector resolution
307, 200 pixels
Infrared Resolution
Yes
Advanced manual focus
Yes
Rugged, ergonomic design for one-handed use
2x and 4x
Digital zoom
产品定位

Capturing and displaying temperature variances makes all the difference when diagnosing problems. The Fluke Ti480 PRO Infrared Camera has increased thermal sensitivity to capture minute differences and the latest Fluke technology for on-screen clarity to make it easy to visual issues in the field. With the enhanced measurement accuracy and the wider dynamic temperature range—up to 1000 °C with NETD as low as 50 mK—technicians can collect precise information for making informed decisions that boost the company’s return on investment.

The Ti480 PRO features sharp on-screen images with clear visual color differentiation to speed troubleshooting. It displays deviations from standard temperatures using multiple Delta-T markers,

allowing users to choose one as a reference point and the others to display a value as a difference. Multiple rectangle markers in-camera identify min/max temperatures for an area of the equipment or an equipment array. The camera distinguishes heat differences more easily with a new palette and a wider array of yellows and greens in the display.

核心参数
Key features
· IFOV with standard lens (spatial resolution):0.93 mRad, D:S 1065:1
· Detector resolution:640 x 480
· Infrared Resolution:307, 200 pixels
· MultiSharp Focus
– Yes, focused near and far, throughout the field of view
· LaserSharp Auto Focus:Yes, for consistently in-focus images
· Laser distance meter
– Yes, calculates distance to the target for precisely focused images and displays distance on screen
· Advanced manual focus:Yes
· Ruggedized touchscreen display:3.5 inch (landscape) 640 x 480 LCD
· Rugged, ergonomic design for one-handed use:Yes
功能与特点
· Increased sensitivity to visualize temperature differences
· Easier to visualize and diagnose issues with sharper onscreen images, multiple rectangle markers and 9 color palettes
· More intuitive visual interface, improved, user-tested, touch screen interface
· More flexibility to visualize target, tiny-to-large with interchangeable smart lenses - no calibration required, 2x and 4x telephoto, wide angle and macro lens compatibility
典型应用
· 电气设备检测
资源下载
· 本页仅列出核心参数,完整技术指标请见 ti480-pro-specs.html
Fluke Corporation · onetest 仪器资源库
本文由 onetest 仪器资源库依据厂商公开资料整理,参数以厂商正式资料为准。

 

 

Fluke Corporation · 红外热像仪

Ti480 PRO 手持红外热像仪 · 详细指标

0.93 mRad, D:S 1065:1 · 640 x 480 · 307, 200 pixels · Yes · Yes · 2x and 4x
产品简介

Capturing and displaying temperature variances makes all the difference when diagnosing problems. The Fluke Ti480 PRO Infrared Camera has increased thermal sensitivity to capture minute differences and the latest Fluke technology for on-screen clarity to make it easy to visual issues in the field. With the enhanced measurement accuracy and the wider dynamic temperature range—up to 1000 °C with NETD as low as 50 mK—technicians can collect precise information for making informed decisions that boost the company’s return on investment.

完整技术指标
Key features
· IFOV with standard lens (spatial resolution):0.93 mRad, D:S 1065:1
· Detector resolution:640 x 480
· Infrared Resolution:307, 200 pixels
· MultiSharp Focus
– Yes, focused near and far, throughout the field of view
· LaserSharp Auto Focus:Yes, for consistently in-focus images
· Laser distance meter
– Yes, calculates distance to the target for precisely focused images and displays distance on screen
· Advanced manual focus:Yes
· Ruggedized touchscreen display:3.5 inch (landscape) 640 x 480 LCD
· Rugged, ergonomic design for one-handed use:Yes
· Digital zoom:2x and 4x
Temperature measurement
· Temperature measurement range (not calibrated below -10 °C):≤-20 °C to 1000 °C (-4 °F to 1832 °F)
· Accuracy
– ±2 °C or 2% (at 25 °C nominal, whichever is greater)
· Thermal sensitivity (NETD)*:≤0.05 °C at 30 °C target temp (50 mK)
· On-screen emissivity correction:Yes (both value and table)
· On-screen reflected background temperature compensation:Yes
· On-screen transmission correction:Yes
Wireless connectivity
· Fluke Connect app compatible
– Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing
· Fluke Connect Assets optional software
– Yes*, assign images to assets and create work orders. Easily compare measurement types in one location
· Fluke Connect Instant Upload
– Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC
· Fluke Connect tool compatible
– Yes*, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen
Adds the context of the visible details to your infrared image
· Picture-In-Picture (PIP):Yes
· Built-in digital camera (visible light):5 MP
Lenses
· Standard lens IFOV (spatial resolution):0.93 mRad, D:S 1065:1
· Standard lens Field of view:34 °H x 24 °V
· Standard lens Minimum focus distance:15 cm (approx. 6 in)
· Standard lens IR-Fusion technology:Picture-In-Picture and full screen
· Optional 2x telephoto smart lens IFOV (spatial resolution):0.46 mRad, D:S 1529:1
· Optional 2x telephoto smart lens Field of view:17 °H x 12 °V
· Optional 2x telephoto smart lens Minimum focus distance:45 cm (approx. 18 in)
· Optional 2x telephoto smart lens IR-Fusion technology:Picture-In-Picture and full screen
· Optional 4x telephoto smart lens IFOV (spatial resolution):0.23 mRad, D:S 2941:1
· Optional 4x telephoto smart lens Field of view:6 °H x 4.5 °V
· Optional 4x telephoto smart lens Minimum focus distance:1.5 cm (approx. 60 in)
· Optional 4x telephoto smart lens IR-Fusion technology:N/A
· Optional wide-angle smart lens IFOV:1.85 mRad, D:S 377:1
· Optional wide-angle smart lens Field of view:48 °H x 34 °V
· Optional wide-angle smart lens Minimum focus distance:15 cm (approx. 6 in)
· Optional wide-angle smart lens IR-Fusion technology:Full screen
· Fast auto toggle between manual and auto modes:Yes
· Fast auto-rescale in manual mode:Yes
· Minimum span (in manual mode):2.0 °C (3.6 °F)
· Minimum span (in auto mode):3.0 °C (5.4 °F)
Data storage and image capture
· Extensive memory options
– Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud for permanent storage
· Image file formats
– Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
· Memory review:Thumbnail and fullscreen review
· Software
– SmartView software - full analysis and reporting software and Fluke Connect system
· Export file formats with SmartView software:Bitmap (.bmp), GIF, JPEG, PNG, TIFF
· Voice annotation
– 60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required
· IR-PhotoNotes:Yes (5 images)
· Text annotation:Yes
· Video recording:Standard and radiometric
· File formats video
– Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
· Streaming video (remote display)
– Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView software on a PC
– via WiFi hotspot to the Fluke Connect app on a smartphone
– or via HDMI to a TV monitor
· Remote control operation
– Yes, through SmartView software or Fluke Connect mobile app
· Auto capture (temperature and interval):Yes
电池
· Battery life
– 2-3 hours per battery (*Actual life varies depending on settings and usage)
· Battery charge time:2.5 hours to full charge
· Battery charging system
– Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
· AC operation
– AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
· Power saving:User selectable sleep and power off modes
Color palettes
· Standard palettes
– 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
· Ultra Contrast palettes
– 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
一般规格
· Frame rate:60 Hz or 9 Hz versions
· Laser pointer:Yes
· LED light (torch):Yes
· Color alarms (temperature alarms)
– High temperature, low temperature, and isotherms (within range)
· Center-point temperature measurement:Yes
· Spot temperature:Hot and cold spot markers
· User-definable spot markers:3 user-definable spot markers
· Center box
– Expandable-contractible measurement box with MIN-MAX-AVG temp display
· Infrared spectral band:7.5 μm to 14 μm (long wave)
· Operating temperature:-10 °C to +50 °C (14 °F to 122 °F)
· Storage temperature:-20 °C to +50 °C (-4 °F to 122 °F)
· Relative humidity:10% to 95% non-condensing
· Safety
– IEC 61010-1: Overvoltage category II, Pollution Degree 2
· Electromagnetic compatibility
– IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A
· Australian RCM:IEC 61326-1
· US FCC:CFR 47, Part 15 Subpart B
· Vibration:0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6
· Shock:25 g, IEC 60068-2-29
· Drop
<div style="margin:0 0 8px;margin-left:6px;padding-left:22px;border-left:2px solid #fdf2df;font-size:15px;lin

全部

 

福禄克官方渠道


厂家联系方式(中国)

公司:福禄克测试仪器(上海)有限公司

客服热线:400-810-3435(法定工作日 8:30-16:30)

邮箱:china-support@fluke.com

官网:www.fluke.com.cn


总部(美国)

公司:Fluke Corporation

地址:6920 Seaway Blvd, Everett, WA 98203, USA

电话:+1-425-347-6100

技术热线(美国):+1-800-873-5853

官网:www.fluke.com


 

0条提问

X

提问

X

回答

暂无视频

 

0条口碑
X

发表口碑

口碑标题
上传图片

ONETEST仪器资源库

联系电话:+86-755-23033660

电子邮箱:info@onetest.cn

Onetest仪器资源库

公众号

Onetest仪器资源库

视频号

Onetest仪器资源库

bilibili

Onetest仪器资源库

小助手

© 2026 Onetest仪器资源库 All Rights Reserved   粤ICP备17028186号-2      粤公网安备44030902003758

AI问答