SECUTEST ST PRIME 是德国 GMC-I(Gossen Metrawatt)推出的安规测试仪(绝缘耐压测试仪)。主要完成绝缘电阻、接地导通等测量项目,适用于电气安全检测。典型指标:Reference Ranges 线路电压 230 V AC ±0.2%;UseNominal 线路电压 90 V … 264
ONETEST 欢迎您
厂商登录 | 入驻
登录 | 注册 购物车 微信公众号厂商登录
SECUTEST ST PRIME (在产)
SECUTEST ST PRIME 是德国 GMC-I(Gossen Metrawatt)推出的安规测试仪(绝缘耐压测试仪)。主要完成绝缘电阻、接地导通等测量项目,适用于电气安全检测。典型指标:Reference Ranges 线路电压 230 V AC ±0.2%;UseNominal 线路电压 90 V … 264 V A;线路电压 90 V … 264 V AC。
核心参数
- Reference Ranges 线路电压:230 V AC ±0.2%
- Line frequency:50 Hz ±2 Hz
- UseNominal 线路电压:90 V … 264 V A
- Nominal line frequency:50 Hz … 400 Hz
- 线路电压:90 V … 264 V AC
- Line frequency:50 Hz … 400 Hz
功能特性
- Test 电流/Test VoltageMeasurement Type
- Measurements at 电压-free objects
- RPE RPE Protective conductor 电阻 PE(PD) - P1 active: PE(PD) - P1
- RINS RINS 绝缘电阻 LN(PD) - PE(PD)
- PHV - P1 5 UMin Determined minimum 电压 value during the set test time
| General | |
| Reference Ranges 线路电压 | 230 V AC ±0.2% |
| Line frequency | 50 Hz ±2 Hz |
| Waveform | Sinusoidal (deviation between RMS 和 rectified values |
| Ambient temperature | +23 °C ±2 K |
| 相对湿度 | 40 … 60% |
| Load resistance | Linear |
| UseNominal 线路电压 | 90 V … 264 V A |
| Nominal line frequency | 50 Hz … 400 Hz |
| 线路电压 waveform | Sinusoidal |
| 温度 | 0 °C … +40 °C |
| 电源 | |
| Supply network | TN, TT, 或 IT |
| 线路电压 | 90 V … 264 V AC |
| Line frequency | 50 Hz … 400 Hz |
| 功耗 | 200 mA DUT: 10 A DUT: 25 A DUT:约 32 VA 约 105 VA 约 280 VA |
| 环境条件 | |
| 工作温度 | +0 ... +40 °C |
| 储存温度 | -20 ... +60 °C |
| 相对湿度 | 最大 75%, 无凝露 allowed |
| 海拔 | 最大 2000 m |
| Place of use | Indoors; outdoors: only within specified ambient condi- tions |
| 电气安全 | |
| 测量 category | Designed for 300 V CAT II (reduced to 250 V CAT II |
| 污染等级 | 2 |
| 防护 | |
| 额定电压 | 230 V |
| 测试电压 | 2.3 kV AC 50 Hz 或 3.3 kV DC (mains circuit/test socket to mains PE terminal, USB, finger contact, test probe(s), test socket) |
| Safety shutdown | At DUT differential current of > 10 mA, shutdown time < 500 ms, can also be switched to > 30 mA with probe current (electronic fuse) during: |
| Fuse links | Mains fuses: 2 × 500 V/16 A T |
| Probe fuse | M 250 V/250 mA 10 A RPE test current (feature G01 only): 1 × T 500 V/16 A |
| 电磁兼容(EMC) | |
| 干扰发射 | EN 55011 class A |
| 抗扰度 | DIN EN 61326-1 |
| 机械设计 | |
| 防护 | Housing: IP 40 |
| 测试 socket | IP 20 (protection against penetration of solid foreign bodies: ≥ 12.0 mm ∅; protection against the ingress of water: not protected) |
| 外壳 | |
| Height with handle | 170 mm |
| 重量 | |
| PRO | 约 2.5 kg |
| ST PRIME | 约 6.0 kgTECHNICAL DATA 24 | 44 SECUTEST ST BASE (10) / SECUTEST ST PRO / SECUTEST ST PRIME / SECULIFE ST BASE (25) |
| 数据接口 s | |
| 发射强度 | 最大 2.5 mW (class II) |
| USB | USB slave for PC connection/remote control 2 2 × USB master, for data entry devices with HID boot interface, for USB flash drive for data backup, for USB flash drive for saving reports as HTML files for |
| Database Number of data records | 50,000 (1 data record = 1 DUT 或 location node 或 customer 或 single 测量) 1Firmware version 3.2.0 和 lower: 12 mA 2Remote control only with extension: “Remote Control via PC (IZYTRONIQ)” ( as standard feature with |
| Table 14 | Influencing Quantities 和 Influence ErrorTECHNICAL DATA 26 | 44 SECUTEST ST BASE (10) / SECUTEST ST PRO / SECUTEST ST PRIME / SECULIFE ST BASE (25) |