HT Italia
HT8 数字万用表 详细指标
Two-pole multifunction test · HT8 is designed to carry out the basic measurements of a digital t…
详细指标
以下为该型号的技术指标,逐表取自官方《HT8 用户手册》(英文版)TECHNICAL SPECIFICATIONS 章节、官方《HT8》数据手册、官网产品页,表内数值按官方表格原样摘录(原文为英文;括号内为单位)。厂家未列出的项目即官网与手册均未给出,未作推测。
技术特性
• 说明:Voltage measurement with LED indication
• Voltage range:12至690V DC/AC (16至400Hz)
• Rated voltages:12/24/50/120/230/400/690V DC/AC (16至400Hz)
• Accuracy:compliance with IEC/EN61243-3:2014
• ELV indications:>50VAC, >50VDC
• Response time:< 1s at 100% of any rated voltage
• Working time:after 30s of continuous measurement, the
• 说明:instrument must make a pause of 240s before
• 说明:starting a new measurement.
• Consumption during measurement:approx. 50mA (battery 3V, measuring 690V AC)
• 说明:Voltage measurement with display indication
• 说明:Accuracy indicated as [%reading + (number of digits)] at 23°C±5°C, <70%HR
技术特性 · AC/DC voltage
• 量程(V):10.0 至 690.0|分辨率(V) 0.1;Precision ±(3%rdg+5digits);输入 200KΩ;Max voltage 690VAC/DC
• Max input current:<3.5mA (at 690V); Automatic AC/DC voltage detection;
• Frequency range:16 - 400Hz; “OL”: Over Range indication
• 说明:Phase detection function
• Voltage range:100 至 690V
• Frequency:50 / 60Hz
• 说明:Phase sequence
• Voltage range:120至400V Phase-Earth
• Frequency range:50/60Hz
• Measuring mode:2 terminals on non-isolated parts
• 说明:Continuity test
• Detection range:0至500kΩ + 50%
• 说明:Lamp test
• Voltage with new battery:approx. 3kV / 240kHz
• Range intensity 200-280 kHz:approx. 100µV/m
• Indications:“Test” LED on
• Charging time before test:<0.5s
• Flashing frequency:2Hz
• Test time:typically <2s
• Working time:may operate in continuous mode
• Consumption during test:approx. 500mA
附件
• 说明:Power supply
• Battery type:2x1.5V alkaline type AAA, IEC LR03
• 说明:Mechanical characteristics
• Dimensions (L x W x H):255 x 60 x 35mm (10 x 2 x 1in)
• Weight (battery included):approx. 170g (6 ounces)
• Mechanical protection:IP64
• 说明:Reference guidelines
• EMC:IEC/EN61326-1
• Insulation:double insulation
• Overvoltage category:CAT III 690V; CAT IV 600V
• Max height:2000m (6562ft)
• Pollution level:2
• Calibration reference temperature:23°C ± 5°C (73°F ± 41°F)
• Operating temperature:-15°C ÷ 55°C (5°F ÷ 131°F)
• Allowable relative humidity:<95%RH
• Storage temperature:-20°C ÷ 70°C (-4°F ÷ 158°F)
• 说明:This instrument satisfies the requirements of Low Voltage Directive 2014/35/EU
• 说明:(LVD) and of EMC Directive 2014/30/EU
• 说明:This instrument satisfies the requirements of European Directive 2011/65/EU (RoHS)
• 说明:and 2012/19/EU (WEEE)
• 说明:7.4.1. Standard accessories
• • Mobile lead L1 (Code:PR9)
• 说明:• Protective cap for test leads, 2 pcs
• 说明:• Adapter for 4mm test lead tip, 2 pcs
• 说明:• Batteries (not inserted)
资源下载
以上规格取自 HT Italia(HT Instruments)官网 HT8 产品页与其官方用户手册 TECHNICAL SPECIFICATIONS 章节,页面版式由 onetest 仪器资源库整理。
HT Italia SRL · onetest 仪器资源库